Thèse de Doctorat
DOI
https://doi.org/10.11606/T.85.2015.tde-16122015-142907
Document
Auteur
Nom complet
Luís Felipe Liambos Mura
Adresse Mail
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
São Paulo, 2015
Directeur
Jury
Santos, Adimir dos (Président)
Carluccio, Thiago
Dias, Mauro da Silva
Diniz, Ricardo
Silva, Fernando Carvalho da
Titre en portugais
Determinação experimental de taxas de reação no 238U e 235U ao longo do raio da pastilha de UO2 do reator IPEN/MB-01
Mots-clés en portugais
captura radiativa
fissão
IPEN/MB-01
pastilhas combustíveis
taxas de reação nuclear
Resumé en portugais
Este trabalho apresenta e consolida uma metodologia alternativa para a determinação de taxas de reação nuclear ao longo da direção radial das pastilhas combustíveis sem necessidade de intensos fluxos neutrônicos. Esta técnica se baseia na irradiação de um disco de UO2 inserido no interior de uma vareta combustível desmontável no núcleo do reator IPEN/MB-01. Após a irradiação são realizadas várias espectrometrias gama do disco utilizando um detector HPGe alternando sequencialmente 6 colimadores de chumbo com diâmetros diferentes. Consequentemente, as reações nucleares de captura radiativa que ocorrem nos átomos de 238U, juntamente com as fissões que ocorrem em ambos 235U e 238U são mensuradas em função de 6 regiões radiais distintas do disco combustível. As correções de eficiência geométrica devido à introdução dos colimadores no sistema de detecção HPGe são determinadas através do código MCNP-5. As medidas de taxa de fissão são realizadas utilizando o 99Mo como radionuclídeo traçador. Esse radionuclídeo foi estudado e provou-se ideal para estas medidas por possuir um comportamento linear de formação, alto rendimento de fissão e principalmente por emitir fótons de baixa energia. As medidas foram efetuadas irradiando discos de UO2 (com enriquecimento de 4,3%) na posição central do reator IPEN/MB-01 a potência de 100 Watts durante uma hora. Algumas medidas foram realizadas utilizando uma luva de cádmio envolta na vareta combustível para determinar as taxas de reação nuclear na faixa de energia epitérmica. Os resultados experimentais obtidos são comparados a cálculos de taxa de reação nuclear via MCNP-5 utilizando a biblioteca de dados ENDF/B-VII.0, os quais apresentaram discrepâncias de no máximo 9% para as taxas de captura no 238U e 14% para as taxas de fissão no U na faixa epitérmica. Foram obtidos valores máximos de 4,5% para incertezas relativas as taxas de captura total e epitérmica e para as taxas de fissão total e epitérmica valores máximos de 11,3%.
Titre en anglais
Experimental determination of nuclear reaction rates in 238U and 235U along of the radius of fuel pellets of the IPEN/MB-01 reactor
Mots-clés en anglais
fission
fuel pellets
IPEN/MB-01
radiative capture
reaction rates
Resumé en anglais
This research presents and consolidates an alternative methodology for determining nuclear reaction rates along the radial direction of the fuel pellets which does not require high neutron flux. This technique is based on irradiating a thin UO2 disk inserted into a removable fuel rod at the IPEN/MB-01 reactor core. Several gamma spectrometries are performed after irradiation using a HPGe detector. Six lead collimators with different diameters are sequentially alternated during this process, thus, the nuclear radioactive capture which occurs in 238U and the fissions which occur in both 235U and 238U are measured according to six different radial regions of the fuel disk. Geometric efficiency corrections due to the introduction of collimators in HPGe detection system are determined by MCNP-5 code. The fission rate measurements are performed using the 99Mo. This radionuclide was studied and proved ideal for these measurements because it is formed in linear behavior in the reactor core, have a high yield fission and emits low-energy photons. Measurements were performed irradiating UO2 disks (with 4.3% enrichment) in the central position of the IPEN/MB-01 core at 100 watts power level during one hour. Some measurements were performed using a cadmium glove wrapped in the fuel rod to determine the nuclear reaction rates in the epithermal energy range. The experimental results obtained are compared with nuclear reaction rate calculations by means of MCNP-5 with ENDF/B-VII.0 data library showing discrepancies of up to 9% in 238U capture rates and 14% for U fission rates for epithermal energies. Uncertainties regarding the nuclear capture rates have maximum values of 4.5% and the fission rates has maximum values of 11.3%.
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
Date de Publication
2015-12-21
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.