  Bookmark and Share
 
 
Mémoire de Maîtrise
DOI
https://doi.org/10.11606/D.85.2013.tde-15042013-100350
Document
Auteur
Nom complet
Ilka Antonia Rios
Adresse Mail
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
São Paulo, 2013
Directeur
Jury
Andrade, Delvonei Alves de (Président)
Carluccio, Thiago
Siqueira, Paulo de Tarso Dalledone
Titre en portugais
Impacto da redução na concentração de Urânio nas placas laterais dos elementos combustíveis do reator IEA-R1 nas análises neutrônica e termo-hidráulica
Mots-clés en portugais
análise neutrônica
análise termo-hidráulica
redução de densidade de urânio
Resumé en portugais
Neste trabalho, propõe-se um estudo para verificação do impacto da redução na concentração de urânio nas placas laterais dos elementos combustíveis do reator IEA-R1, nas análises neutrônica e termo-hidráulica. Ao se desenvolver o referido trabalho, reproduziu-se estudo conduzido anteriormente pelo IPEN-CNEN/SP, simulando a queima de elementos combustíveis, cujas placas laterais apresentam densidade de urânio reduzida para 50, 60 e 70% em relação às demais placas do elemento combustível. Tal estudo inicia-se com a análise neutrônica, cujo primeiro passo é o cálculo das seções de choque dos materiais presentes no núcleo a partir de suas concentrações iniciais, com a utilização do código computacional HAMMER; o segundo passo é o cálculo dos fluxos de nêutrons dos grupos rápido e térmico e das densidades de potência nos elementos combustíveis estudados em modelagem do núcleo feita no código computacional CITATION, que utiliza os dados gerados pelo HAMMER. Terminada a análise neutrônica e definidos os elementos combustíveis mais críticos com maior densidade de potência, executa-se a análise termo-hidráulica, que utiliza o modelo termo-hidráulico MCTR-IEA-R1, o qual é baseado no pacote comercial EES. A densidade de potência gerada pelo CITATION é utilizada como dado de entrada da análise termo-hidráulica nas equações de balanço de energia do modelo para o cálculo das temperaturas nos pontos de interesse. Neste trabalho, é feita a comparação da operação do reator com três diferentes densidades de urânio nas placas laterais. Concluiu-se que a redução da densidade de urânio contribui para que a temperatura da superfície do revestimento não ultrapasse o limite estabelecido como condição de operação do reator; não há impacto significativo na queima final dos elementos combustíveis, nem na reatividade do reator IEA-R1. A redução de urânio nas placas laterais dos elementos combustíveis do reator IEA-R1 mostrou ser uma opção viável para evitar problemas de corrosão devido a altas temperaturas.
Titre en anglais
Uranium density reduction on fuel element side plates assessment
Mots-clés en anglais
neutronic analysis
thermal-hydraulics analysis
uranium density reduction
Resumé en anglais
This master thesis presents a study to verify the impact of the uranium concentration reduction in the side plates of the reactor IEA-R1 fuel elements on the neutronic and thermal-hydraulic analyses. To develop such study, a previous IPEN-CNEN/SP research was reproduced by simulating the fuel elements burn-up, with side plate uranium density reduced to 50, 60 and 70% of the standard fuel element plates. This research begins with the neutronic analysis using the computer code HAMMER and the first step consists in the calculation of the cross section of all materials presented at the reactor core, with their initial concentration; the second step consists in the calculation of the fast and thermal neutron group fluxes and power densities for fuel elements using the computer code CITATION. HAMMER output data is used as input data. Once the neutronic analysis is finished and the most critical fuel elements with highest power density have been defined, the thermal-hydraulics analysis begins. This analysis uses MCTR-IEA-R1 thermal-hydraulics model, which equations are solved by commercial code EES. Thermal-hydraulics analysis input is the power density data calculated by CITATION: it is considered the highest power density on each fuel element, where there is a higher energy release and, consequently, higher temperatures. This data is used on energy balance equations to calculate temperatures on critical fuel element regions. Reactor operation comparison for three different uranium densities on fuel side plates is presented. Uranium density reduction contributes to the cladding surface temperature to remain below the established limit, as reactor operation safety requirement and it does not affect significantly fuel element final burn-up nor reactor reactivity. The reduction of uranium in the side plates of the fuel elements of the IEA-R1 showed to be a viable option to avoid corrosion problems due to high temperatures.
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
2013RiosImpacto.pdf (1.55 Mbytes)
Date de Publication
2013-04-16
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.