Disertación de Maestría
DOI
https://doi.org/10.11606/D.85.2013.tde-15042013-100350
Documento
Autor
Nombre completo
Ilka Antonia Rios
Dirección Electrónica
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
São Paulo, 2013
Director
Tribunal
Andrade, Delvonei Alves de (Presidente)
Carluccio, Thiago
Siqueira, Paulo de Tarso Dalledone
Título en portugués
Impacto da redução na concentração de Urânio nas placas laterais dos elementos combustíveis do reator IEA-R1 nas análises neutrônica e termo-hidráulica
Palabras clave en portugués
análise neutrônica
análise termo-hidráulica
redução de densidade de urânio
Resumen en portugués
Neste trabalho, propõe-se um estudo para verificação do impacto da redução na concentração de urânio nas placas laterais dos elementos combustíveis do reator IEA-R1, nas análises neutrônica e termo-hidráulica. Ao se desenvolver o referido trabalho, reproduziu-se estudo conduzido anteriormente pelo IPEN-CNEN/SP, simulando a queima de elementos combustíveis, cujas placas laterais apresentam densidade de urânio reduzida para 50, 60 e 70% em relação às demais placas do elemento combustível. Tal estudo inicia-se com a análise neutrônica, cujo primeiro passo é o cálculo das seções de choque dos materiais presentes no núcleo a partir de suas concentrações iniciais, com a utilização do código computacional HAMMER; o segundo passo é o cálculo dos fluxos de nêutrons dos grupos rápido e térmico e das densidades de potência nos elementos combustíveis estudados em modelagem do núcleo feita no código computacional CITATION, que utiliza os dados gerados pelo HAMMER. Terminada a análise neutrônica e definidos os elementos combustíveis mais críticos com maior densidade de potência, executa-se a análise termo-hidráulica, que utiliza o modelo termo-hidráulico MCTR-IEA-R1, o qual é baseado no pacote comercial EES. A densidade de potência gerada pelo CITATION é utilizada como dado de entrada da análise termo-hidráulica nas equações de balanço de energia do modelo para o cálculo das temperaturas nos pontos de interesse. Neste trabalho, é feita a comparação da operação do reator com três diferentes densidades de urânio nas placas laterais. Concluiu-se que a redução da densidade de urânio contribui para que a temperatura da superfície do revestimento não ultrapasse o limite estabelecido como condição de operação do reator; não há impacto significativo na queima final dos elementos combustíveis, nem na reatividade do reator IEA-R1. A redução de urânio nas placas laterais dos elementos combustíveis do reator IEA-R1 mostrou ser uma opção viável para evitar problemas de corrosão devido a altas temperaturas.
Título en inglés
Uranium density reduction on fuel element side plates assessment
Palabras clave en inglés
neutronic analysis
thermal-hydraulics analysis
uranium density reduction
Resumen en inglés
This master thesis presents a study to verify the impact of the uranium concentration reduction in the side plates of the reactor IEA-R1 fuel elements on the neutronic and thermal-hydraulic analyses. To develop such study, a previous IPEN-CNEN/SP research was reproduced by simulating the fuel elements burn-up, with side plate uranium density reduced to 50, 60 and 70% of the standard fuel element plates. This research begins with the neutronic analysis using the computer code HAMMER and the first step consists in the calculation of the cross section of all materials presented at the reactor core, with their initial concentration; the second step consists in the calculation of the fast and thermal neutron group fluxes and power densities for fuel elements using the computer code CITATION. HAMMER output data is used as input data. Once the neutronic analysis is finished and the most critical fuel elements with highest power density have been defined, the thermal-hydraulics analysis begins. This analysis uses MCTR-IEA-R1 thermal-hydraulics model, which equations are solved by commercial code EES. Thermal-hydraulics analysis input is the power density data calculated by CITATION: it is considered the highest power density on each fuel element, where there is a higher energy release and, consequently, higher temperatures. This data is used on energy balance equations to calculate temperatures on critical fuel element regions. Reactor operation comparison for three different uranium densities on fuel side plates is presented. Uranium density reduction contributes to the cladding surface temperature to remain below the established limit, as reactor operation safety requirement and it does not affect significantly fuel element final burn-up nor reactor reactivity. The reduction of uranium in the side plates of the fuel elements of the IEA-R1 showed to be a viable option to avoid corrosion problems due to high temperatures.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
2013RiosImpacto.pdf (1.55 Mbytes)
Fecha de Publicación
2013-04-16
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.