Mémoire de Maîtrise
DOI
https://doi.org/10.11606/D.85.2010.tde-12082011-164705
Document
Auteur
Nom complet
Paula Cristina Guimarães Antunes
Adresse Mail
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
São Paulo, 2010
Directeur
Jury
Siqueira, Paulo de Tarso Dalledone (Président)
Milián, Félix Más
Rodrigues, Laura Natal
Titre en portugais
Reconstrução de objetos simuladores segmentados aplicáveis à dosimetria de pele
Mots-clés en portugais
algoritmo de segmentação
dosimetria de pele
MCNP
objeto simulador segmentado
radioterapia
Resumé en portugais
A radioterapia é uma modalidade terapêutica que utiliza radiações ionizantes para erradicar as células neoplásicas do organismo humano. Um dos requisitos para o sucesso desta metodologia de tratamento está na utilização adequada dos sistemas de planejamento, os quais, dentre outras informações, estimam a dose a ser administrada aos pacientes. Atualmente, códigos de transporte de radiação têm proporcionado grandes subsídios a estes sistemas de planejamento, uma vez que viabilizam avaliações dosimétricas acuradas nos órgãos e tecidos específicos de um paciente. O modelo utilizado por estes códigos para descrever a anatomia humana de forma realista é denominado Objeto Simulador Segmentado (OSS), que consiste na representação das estruturas anatômicas do corpo em discretos elementos de volume (voxels), os quais são diretamente associados aos dados tomográficos. Atualmente, os OSS possíveis de serem inseridos e processados pelo código de transporte MCNP (Monte Carlo N-Particle), apresentam voxels com resoluções da ordem de 3-4 mm. No entanto, tal resolução compromete a discriminação de algumas estruturas finas do corpo, tais como a pele. Neste contexto, o presente estudo propõe a criação de uma rotina de cálculo que discrimine a região da pele, com espessura e localização próximas do real, nos OSS e os habilite para avaliações dosimétricas acuradas. A metodologia proposta consiste na manipulação dos elementos de volume dos OSS de forma a segmentá-los e subdividi-los em diferentes espessuras de pele. A fim de validar os dados obtidos por cálculos, foram realizadas avaliações experimentais de dosimetria de pele em objetos simuladores antropomórficos com dosímetros termoluminescentes. Verificou-se, ao longo deste estudo, a importância de discriminar a região da pele com localização e espessuras próximas do real, uma vez que foram encontradas diferenças significativas entre as estimativas de dose absorvida na região pelas diferentes representações. A metodologia proposta neste estudo far-se-á útil para avaliações dosimétricas acuradas da região de pele para diversos procedimentos radioterápicos, com particular interesse na radioterapia com feixe de elétrons, na qual se destaca a terapia de irradiação de corpo inteiro (TSET Total Skin Electron Therapy), procedimento radioterápico em implementação no Hospital das Clínicas da Faculdade de Medicina da Universidade de São Paulo (HC-FMUSP).
Titre en anglais
Reconstruction of voxel phantoms for skin dosimetry
Mots-clés en anglais
MCNP
radiotherapy
skin dosimetry
Resumé en anglais
Radiotherapy is a therapeutic modality that utilizes ionizing radiation for the destruction of neoplastic human cells. One of the requirements for this treatment methodology success lays on the appropriate use of planning systems, which performs, among other information, the patients dose distribution estimate. Nowadays, transport codes have been providing huge subsidies to these planning systems, once it enables specific and accurate patient organ and tissue dosimetry. The model utilized by these codes to describe the human anatomy in a realistic way is known as voxel phantoms, which are represented by discrete volume elements (voxels) directly associated to tomographic data. Nowadays, voxel phantoms doable of being inserted and processed by the transport code MCNP (Monte Carlo N-Particle) presents a 3-4 mm image resolution; however, such resolution limits some thin body structure discrimination, such as skin. In this context, this work proposes a calculus routine that discriminates this region with thickness and localization in the voxel phantoms similar to the real, leading to an accurate dosimetric skin dose assessment by the MCNP code. Moreover, this methodology consists in manipulating the voxel phantoms volume elements by segmenting and subdividing it in different skin thickness. In addition to validate the skin dose calculated data, a set of experimental evaluations with thermoluminescent dosimeters were performed in an anthropomorphic phantom. Due to significant differences observed on the dose distribution of several skin representations, it was found that is important to discriminate the skin thickness similar to the real. The presented methodology is useful to obtain an accurate skin dosimetric evaluation for several radiotherapy procedures, with particular interest on the electron beam radiotherapy, in which highlights the whole body irradiation therapy (TSET), a procedure under implementation at the Hospital das Clínicas da Faculdade de Medicina da Universidade de São Paulo (HC-FMUSP).
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
Date de Publication
2011-08-15
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.