• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Disertación de Maestría
DOI
https://doi.org/10.11606/D.85.2014.tde-08102014-084019
Documento
Autor
Nombre completo
Alexandre Fonseca Póvoa da Silva
Dirección Electrónica
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
São Paulo, 2014
Director
Tribunal
Bitelli, Ulysses D'Utra (Presidente)
Gonçalez, Odair Lelis
Lima, Ana Cecilia de Souza
Título en portugués
Calibração da potência do reator IPEN/MB-01 na configuração cilíndrica de menor excesso de reatividade obtida a partir da medida absoluta do fluxo médio de nêutrons
Palabras clave en portugués
calibração de potência
canais nucleares
fluxo de nêutrons térmicos
folhas de ouro
reator IPEN/MB-01
Resumen en portugués
A ativação de folhas de ouro é uma das técnicas mais usadas para obter dados experimentais e assim comparar os resultados obtidos com aqueles calculados usando metodologias específicas e seus respectivos dados nucleares. Através da irradiação de folhas de ativação e posterior medida da atividade nelas induzida é possível determinar o fluxo de nêutrons no local da irradiação. O nível da potência de operação do reator é um parâmetro diretamente proporcional ao fluxo médio de nêutrons no núcleo do reator. O objetivo deste trabalho é obter, pela irradiação de folhas de ouro posicionadas simetricamente dentro do núcleo, utilizando a configuração cilíndrica que apresenta o menor excesso de reatividade, a potência gerada pela distribuição espacial do fluxo de nêutrons térmicos e epitérmicos no núcleo do reator IPEN/MB-01 e assim, calibrar seus canais nucleares. As folhas foram colocadas em uma placa de Lucite e irradiadas com e sem cobertura de cádmio, para se obter o valor absoluto de nêutrons térmicos e epitérmicos. A correlação entre a potência média do fluxo de nêutrons, como resultado da irradiação das folhas de ouro e, a potência média obtida a partir da aquisição de valores digitais dos canais nucleares, permite calibrar os canais nucleares do reator. Em 2008 foi feita a correlação para a configuração de núcleo retangular que resultou em uma calibração específica do nível de potência de operação para esta configuração geométrica de núcleo. Assim, esta calibração não pode ser utilizada como referência para a configuração em questão, ou seja, a cilíndrica, pois os parâmetros nucleares de distribuição de fluxo não são os mesmos, pois a distribuição difere para cada tipo de distribuição geométrica de núcleo. Além disto, o conhecimento preciso da potência de operação do reator nos permite obter os valores absolutos de fluxos de nêutrons e assim validar a metodologia de cálculo utilizada para este propósito.
Título en inglés
Power calibration of the IPEN/MB-01 reactor for the cylindrical configuration of minor reactivity excesso obtained from the measurements of the absolut average neutron flux
Palabras clave en inglés
gold foils
nuclear channels
power calibration
reactor IPEN/MB-01
termal neutron flux
Resumen en inglés
The activation foils is one of the most used techniques to obtain nuclear parameters and thus compare the results with the calculated ones using specific methodologies and its nuclear data. Through the irradiation in the activation foils and ulterior measurement on its induced activity, it is possible to determine the neutron flux in the position where they were irradiated. The power level operation of the reactor is a parameter directly proportional to the average neutron flux in the core. The objective of this work is to obtain, by irradiating gold foils positioned symmetrically into the core for a cylindrical configuration, that presents the minor reactivity excess, the power generated through the spatial thermal and epitermal neutron flux distribution in the core of the IPEN/MB-01 Reactor, and thus calibrate its nuclear channels. The foils were put in a Lucite plate and irradiated with and without cadmium covered small plates, to obtain the absolute thermal and epithermal neutron flux. The correlation between the average power neutron flux, as a result of the gold foil´s irradiation and, the average power obtained by the digital values of the nuclear channels, allows the calibration of the nuclear channels of the reactor. This same correlation was done in 2008 with the reactor in a rectangular configuration, which resulted in a specific calibration of the power level operation for this geometric configuration of the core. Thus this calibration cannot be used as a reference for the actual configuration, the cylindrical one, because the nuclear parameters of the neutrons distribution are not the same, it changes for every geometric configuration of the core. Furthermore, the precise knowledge of the power neutron flux allows us to obtain absolute value of the neutron flux and thus validate the methodology used for this purpose.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Fecha de Publicación
2014-10-09
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.