• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Master's Dissertation
DOI
https://doi.org/10.11606/D.85.2013.tde-04072013-145137
Document
Author
Full name
Giovanni Laranjo de Stefani
E-mail
Institute/School/College
Knowledge Area
Date of Defense
Published
São Paulo, 2013
Supervisor
Committee
Diniz, Ricardo (President)
Deppman, Airton
Santos, Adimir dos
Title in Portuguese
Sobre a técnica de Rod Drop em medidas de reatividade integral em bancos de controle e segurança de reatores
Keywords in Portuguese
detectores
integral
reatividade
Rod Drop
sombreamento
Abstract in Portuguese
Este trabalho apresenta um estudo sobre o efeito de sombreamento em detectores de nêutrons, quando estes são utilizados em medidas de reatividade com a técnica de rod drop. O sombreamento pode ser entendido como uma mudança na eciência dos detectores, quando esta é dada em nêutrons detectados/ssão ocorrida no reator, sendo mais evidente nos detectores mais próximos ao banco sendo inserido. O método de análise, fundamentalmente teórica, baseou-se em simulações do reator IPEN/MB-01 utilizando o código CITATION e o programa MCNP. Em ambos os casos, os resultados são estáticos, mostrando os uxos neutrônicos apenas em duas situações: antes da inserção do banco, e após sua inserção. A reatividade, neste caso, é obtida utilizandose a expressão derivada da técnica de source jerk. Em adição ao estudo teórico, os dados de um experimento de rod drop realizado no reator IPEN/MB-01 também foram utilizados. Neste caso, a reatividade foi obtida com o método de cinética inversa, já que os dados experimentais são constituídos de valores que variam no tempo. Em todos os casos, fatores de correção para o efeito de sombreamento são propostos.
Title in English
About the technique of Rod Drop in measures of rod worth in security and control rods of nuclear reactors
Keywords in English
detector
reactivity
Rod Drop
shadowing
worth
Abstract in English
This work presents a study on the eect of shading in neutron detectors, when used in measures of reactivity with the rod drop technique. Shading can be understood as a change in the eciency of the detectors, when it is given in detected neutrons / ssion occurred in the reactor, more evident in the detectors closest to the bank being inserted. The method of analysis was based on simulations of reactor IPEN/MB-01, using the code CITATION and MCNP program. In both cases, the results were static, showing Neutronic ows in only two situations: before insertion of the control rod and after insertion. The measure of reactivity in this case was achieved using the expression derived from the source jerk technique. In addition to theoretical study, data from a rod drop experiment conducted in the reactor IPEN/MB-01 were also used. In this case, the reactivity was obtained using inverse kinetic method, since experimental data were set of values that vary with time. In all cases, correction factors for the shadowing eect have been proposed.
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.
2013StefaniSobre.pdf (4.34 Mbytes)
Publishing Date
2013-07-30
 
WARNING: Learn what derived works are clicking here.
All rights of the thesis/dissertation are from the authors
CeTI-SC/STI
Digital Library of Theses and Dissertations of USP. Copyright © 2001-2024. All rights reserved.