• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Disertación de Maestría
DOI
https://doi.org/10.11606/D.85.2009.tde-02032010-081459
Documento
Autor
Nombre completo
Daniel Massami Hirata
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
São Paulo, 2009
Director
Tribunal
Sabundjian, Gaianê (Presidente)
Cabral, Eduardo Lobo Lustosa
Gibelli, Sonia Maria Orlando
Título en portugués
Estimativa da frequência de danos ao núcleo devido a perda de refrigerante primário e bloqueio de canal de refrigeração do Reator de Pesquisas IEA-R1 do IPEN -CNEN/SP -APS nível1
Palabras clave en portugués
Análise Probabilística de Segurança
Confiabilidade e Reatores de Pesquisa.
Resumen en portugués
Neste trabalho é aplicada a metodologia da Análise Probabilística de Segurança nível 1 ao reator IEA-R1. Inicialmente são descritos os eventos iniciadores de acidentes identificados no reator para duas categorias: perda de vazão e perda de refrigerante primário. Dentre eles foram escolhidos dois eventos iniciadores para análise mais detalhada do acidente e obtenção da estimativa da freqüência de danos ao núcleo devido a sua ocorrência. Foram selecionados os seguintes eventos iniciadores: bloqueio de canal de refrigeração (maior probabilidade) e perda de refrigerante por grande ruptura da tubulação do circuito primário (maiores consequências). Para modelar a evolução do acidente a partir da ocorrência do evento iniciador e da atuação ou não dos sistemas de segurança utilizou-se Árvore de Eventos. Através de Árvore de Falhas, também foi avaliada a confiabilidade dos seguintes sistemas: sistema de desligamento do reator, isolamento da piscina, sistema de resfriamento de emergência (SRE) e sistema elétrico. Como resultados foram obtidas as estimativas das frequências de danos ao núcleo do reator e as probabilidades de falha dos sistemas analisados. As freqüências de danos ao núcleo mostraram-se dentro das margens esperadas, sendo da mesma ordem de grandeza que os encontrados para reatores similares. As confiabilidades dos sistemas de desligamento do reator, de isolamento da piscina e do SRE foram satisfatórias para as condições em que estes sistemas foram exigidos. Todavia, para o sistema elétrico seria recomendável uma análise para verificar a possibilidade de modernização a fim de aumentar a sua confiabilidade.
Título en inglés
ESTIMATIVE OF CORE DAMAGE FREQUENCY IN IPEN`S IEA-R1 RESEARCH REACTOR (PSA LEVEL 1) DUE TO THE INITIATING EVENT OF LOSS OF COOLANT CAUSED BY LARGE RUPTURE IN THE PIPE OF THE PRIMARY CIRCUIT
Palabras clave en inglés
Análise Probabilística de Segurança
Confiabilidade e Reatores de Pesquisa.
Resumen en inglés
This work applies the methodology of Probabilistic Safety Assessment Level 1 to the research reactor IEA-R1 IPEN-CNEN/SP. Two categories of identified initiating events of accidents in the reactor are studied: loss of flow and loss of primary coolant. Among the initiating events, blockage of flow channel and loss of cooling fluid by major pipe rupture in the primary circuit are chosen for a detailed analysis. The event tree technique is used to analyze the evolution of the accident, including the actuation or the fail of actuation of the safety systems and the reactor damages. Using the fault tree the reliability of the following reactor safety systems is evaluated: reactor shutdown system, isolation of the reactor pool, Emergency Core Cooling System (ECCS) and the electric system. Estimative for the frequency of damage to the reactor core and the probability of failure of the analyzed systems are calculated. The estimated values for the frequencies of core damage are within the expected margins and are of the same order of magnitude as those found for similar reactors. The reliability of the reactor shutdown system, isolation of the reactor pool and ECCS are satisfactory for the conditions these systems are required. However, for the electric system it is suggested an upgrade to increase its reliability. .
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Fecha de Publicación
2010-03-30
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.