• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Master's Dissertation
DOI
https://doi.org/10.11606/D.85.2011.tde-01032012-103426
Document
Author
Full name
Cesar Augusto Domingues Loureiro
E-mail
Institute/School/College
Knowledge Area
Date of Defense
Published
São Paulo, 2011
Supervisor
Committee
Santos, Adimir dos (President)
Diniz, Ricardo
Silva, Fernando Carvalho da
Title in Portuguese
Desenvolvimento e aplicação da reatímetro digital subcritico
Keywords in Portuguese
cinética inversa
cinética pontual
medição de reatividade
reatímetro
subcrítico
Abstract in Portuguese
Em testes físicos de reatores que são realizados na criticalização, após uma troca de combustível, por exemplo, como ocorre nos reatores PWR, é muito importante monitorar continuamente a reatividade durante o processo de criticalização. Medir a reatividade utilizando o método da Cinética Inversa é um processo bastante utilizado durante a operação de um reator nuclear, e é possível determinar a reatividade em tempo real baseado nas equações de cinética pontual. Essa técnica é aplicada com sucesso a altas potências, ou em núcleos que trabalham sem a existência de uma fonte externa, já que nesse caso o Termo Fonte na equação de cinética pontual pode ser desprezado. Para operações a baixas potências, a contribuição da fonte de nêutrons precisa ser levada em consideração, e isso implica em conhecer um valor proporcional à intensidade da fonte e, portanto esse valor precisa ser determinado. O Método dos Mínimos Quadrados em Cinética Inversa (Least Square Inverse Kinetics Method LSIKM) foi testado com modelo teórico e aplicado em experimentos no Reator Nuclear IPEN/MB-01 para a determinação do Termo Fonte com a utilização de um reatímetro que ignora o Termo Fonte em primeira instância. Após a determinação da Fonte S de forma consistente, seu valor foi inserido ao algoritmo de Cinética Inversa, e utilizando dados de detectores durante a criticalização, o reatímetro com Termo Fonte foi usado para medir a reatividade no domínio subcrítico, nos passos de criticalização, após experimento.
Title in English
Development and application of a subcritical digital reactivity meter
Keywords in English
inverse kinetics
point kinetics
reactivity measurement
reactivity meter
subcritical
Abstract in English
In Physical tests which are made during the approach process, after a fuel change, as an example, like those that occur in PWR reactors, monitoring the level of subcritical condition continuously is very important. Measuring reactivity by inverse kinetics method is a process widely used during a nuclear reactor operation, and it is possible to determine reactivity on line, based on the point kinetics equations. This method is applied successfully when the reactor works without an external neutron source, or while the reactor is in the critical domain, because in these cases, the source term in point kinetics equations might be neglected. However, when the power is too low, the source contribution is not negligible and must be taken into account, and this need imply a knowledge of a value proportional to the source intensity, and so this value must be determined. The LSIKM (Least Square Inverse Kinetics Method) has been tested in a theoretical model and applied experimentally in the IPEN/MB Nuclear Reactor facility for the determination of the source term, by using a reactivity meter neglecting the source term in first instance. After the determination of the value proportional to the source contribution, this value has been inserted into the algorithm of inverse kinetics, and using neutron detector data during the approach to critical process, the reactivity meter with source term was used to determinate the reactivity in the subcritical domain, after the experiment performing.
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.
Publishing Date
2012-04-04
 
WARNING: Learn what derived works are clicking here.
All rights of the thesis/dissertation are from the authors
CeTI-SC/STI
Digital Library of Theses and Dissertations of USP. Copyright © 2001-2024. All rights reserved.