Auteur
Nom complet
Iremar Alves da Silva Junior
Adresse Mail
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
São Paulo, 2012
Directeur
Jury
Potiens, Maria da Penha Albuquerque (Président)
Bottaro, Marcio
Silva, Teógenes Augusto da
Titre en portugais
Desenvolvimento e implantação de um sistema automatizado para adequação do processo de calibração de monitores de radiação gama
Mots-clés en portugais
automação
calibração
irradiador gama
metrologia
monitor de radiação
Resumé en portugais
Esse trabalho foi desenvolvido com a finalidade de melhorar a qualidade dos serviços de calibração e testes de monitores de radiação gama, prestados pelo Laboratório de Calibração de Instrumentos do IPEN, assim como diminuir a dose ocupacional dos técnicos envolvidos no processo de calibração, seguindo os princípios de proteção radiológica. Foi realizado o desenvolvimento e a implantação de um sistema automatizado para o processo de calibração de monitores de radiação gama, constituido por (i) um dispositivo pneumático de troca dos atenuadores e (ii) uma mesa de posicionamento, ambos acionados remotamente por intermédio de um painel de comando. Também fez parte a implantação de um Sistema Irradiador Caesa-Gammatron, que aumentou o intervalo de taxa de kerma no ar, devido sua alta atividade em relação ao sistema atualmente em uso no laboratório de calibração com radiação gama. Para isso, foi necessária a instalação de um dispositivo atenuador controlado remotamente nesse sistema irradiador. Por último foi realizado uma avaliação da redução da dose ocupacional.
Titre en anglais
Development and implementation of an automated system for adequation of the calibration process for gamma radiation monitors
Mots-clés en anglais
automation
calibration
gamma irradiator
metrology
radiation monitor
Resumé en anglais
This work was developed with the aim of improving the quality of the services of calibration and tests of gamma radiation monitors - provided by the IPEN Laboratory of Instrument Calibration - as well as reducing the occupational dose in technicians involved in the process of calibration, following the principles of radiation protection. In this study it was carried out the development and implementation of a system for adequation of the process of gamma radiation monitors calibration. It is constituted by (i) a pneumatic dispositive to exchange the attenuators and (ii) a positioning table, both actuated through a control panel. System was also implemented. A Caesa-Gammatron Irradiator, which increased the range of the air kerma rates, due to its activity higher than the current system of gamma radiation in use in the calibration laboratory. Hence, it was necessary the installation of remotely controlled in the attenuator dispositive in this irradiator system. Lastly, it was carried out an evaluation in the reduction of the occupational doses.
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
Date de Publication
2013-06-06
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.