Thèse de Doctorat
DOI
https://doi.org/10.11606/T.85.2015.tde-30072015-132845
Document
Auteur
Nom complet
Amanda Bravim
Adresse Mail
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
São Paulo, 2015
Directeur
Jury
Rodrigues, Letícia Lucente Campos (Président)
Hormaza, Joel Mesa
Pereira, Maria da Conceição Costa
Rocha, Felícia Del Gallo
Todo, Alberto Saburo
Titre en portugais
Aplicação das técnicas de dosimetria termoluminescente (TL) e luminescência opticamente estimulada (OSL) na determinação de curvas de isodose em uma simulação de tratamento de câncer pela técnica de radioterapia em arco modulado volumétrico - VMAT
Mots-clés en portugais
curvas de isodose
dosimetria
luminescência opticamente estimulada
radioterapia em arco modulado volumétrico
termoluminescência
Resumé en portugais
A Radioterapia em Arco Modulado Volumétrico (VMAT) é uma técnica avançada de Radioterapia de Intensidade Modulada (IMRT). Esse avanço na técnica é devido à rotação contínua do gantry juntamente com a modulação do feixe de radiação proporcionando um tempo menor no tratamento do paciente. O objetivo desse trabalho é a verificação de curvas de isodose em uma simulação de um tratamento de vértebra com proteção de medula espinhal utilizando as técnicas de dosimetria termoluminescente (TL) e luminescência opticamente estimulada (OSL) e os dosímetros de LiF:Mg,Ti (TLD-100), CaSO4:Dy e Al2O3:C e microdosímetros de LiF:Mg,Ti (TLD-100). Os dosímetros foram caracterizados com a utilização de placas de PMMA de 30x30 cm2 e diversas espessuras. Todas as irradiações foram feitas utilizando o acelerador linear Truebeam STx da Varian do Hospital Israelita Albert Einstein, com feixe de fótons de 6 MV. Após a caracterização dos dosímetros, os mesmos foram irradiados seguindo a simulação do planejamento escolhido e utilizando um objeto simulador de PMMA produzido para medidas de VMAT. Essa irradiação teve como finalidade verificar através das duas técnicas de dosimetria as curvas de isodose dessa simulação de tratamento. Todos os tipos de dosímetros apresentaram resultados satisfatórios na verificação das curvas de isodose utilizando ambas as técnicas de dosimetria. Porém, analisando a complexidade das curvas de isodose e a possibilidade das curvas estarem muito próximas, o microdosímetro de LiF:Mg,Ti se mostrou o mais apropriado para o uso devido à suas pequenas dimensões. Em relação à melhor técnica, como ambas apresentaram resultados satisfatórios, a técnica TL é a que apresenta menor complexidade em ser utilizada, pois a maioria dos Departamentos de Radioterapia já possuem um Laboratório para leitura TL. A técnica OSL exige mais cuidados e maior investimento do Departamento.
Titre en anglais
Application of the thermoluminescent (TL) and optically stimulated luminescence (OSL) dosimetry techniques to determinate the isodose curves in a cancer treatment planning simulation using volumetric modulated arc therapy - VMAT
Mots-clés en anglais
dosimetry
isodose curves
optically stimulated luminescence
thermoluminescence
volumetric modulated arc therapy
Resumé en anglais
The Volumetric Modulated Arc Therapy (VMAT) is an advance technique of Intensity Modulated Radiation Therapy (IMRT). This progress is due to the continuous gantry rotation with the radiation beam modulation providing lower time of the patient treatment. This research aimed the verification of the isodose curves in a simulation of a vertebra treatment with spinal cord protection using the thermoluminescent (TL) and optically stimulated luminescence (OSL) dosimetry techniques and theLiF:Mg,Ti (TLD-100), CaSO4:Dy and Al2O3:C dosimeters and LiF:Mg,Ti microdosimeters (TLD-100). The dosimeters were characterized using PMMA plates of 30x30x30 cm3 and different thickness. All irradiations were done using Truebeam STx linear accelerator of Hospital Israelita Albert Einstein, with 6 MV photons beam. After the dosimeter characterization, they were irradiated according the specific planning simulation and using a PMMA phantom developed to VMAT measurements. This irradiation aimed to verify the isodose curves of the treatment simulation using the two dosimetry techniques. All types of dosimeters showed satisfactory results to determine the dose distribution but analysing the complexity of the isodose curves and the proximity of them, the LiF:Mg,Ti microdosimeter showed the most appropriate for use due to its small dimensions. Regarding the best technique, as both technique showed satisfactory results, the TL technique presents less complex to be used because the most of the radiotherapy departments already have a TL laboratory. The OSL technique requires more care and greater investment in the hospital.
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
Date de Publication
2015-08-07
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.