• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Doctoral Thesis
DOI
https://doi.org/10.11606/T.85.2015.tde-30072015-132845
Document
Author
Full name
Amanda Bravim
E-mail
Institute/School/College
Knowledge Area
Date of Defense
Published
São Paulo, 2015
Supervisor
Committee
Rodrigues, Letícia Lucente Campos (President)
Hormaza, Joel Mesa
Pereira, Maria da Conceição Costa
Rocha, Felícia Del Gallo
Todo, Alberto Saburo
Title in Portuguese
Aplicação das técnicas de dosimetria termoluminescente (TL) e luminescência opticamente estimulada (OSL) na determinação de curvas de isodose em uma simulação de tratamento de câncer pela técnica de radioterapia em arco modulado volumétrico - VMAT
Keywords in Portuguese
curvas de isodose
dosimetria
luminescência opticamente estimulada
radioterapia em arco modulado volumétrico
termoluminescência
Abstract in Portuguese
A Radioterapia em Arco Modulado Volumétrico (VMAT) é uma técnica avançada de Radioterapia de Intensidade Modulada (IMRT). Esse avanço na técnica é devido à rotação contínua do gantry juntamente com a modulação do feixe de radiação proporcionando um tempo menor no tratamento do paciente. O objetivo desse trabalho é a verificação de curvas de isodose em uma simulação de um tratamento de vértebra com proteção de medula espinhal utilizando as técnicas de dosimetria termoluminescente (TL) e luminescência opticamente estimulada (OSL) e os dosímetros de LiF:Mg,Ti (TLD-100), CaSO4:Dy e Al2O3:C e microdosímetros de LiF:Mg,Ti (TLD-100). Os dosímetros foram caracterizados com a utilização de placas de PMMA de 30x30 cm2 e diversas espessuras. Todas as irradiações foram feitas utilizando o acelerador linear Truebeam STx da Varian do Hospital Israelita Albert Einstein, com feixe de fótons de 6 MV. Após a caracterização dos dosímetros, os mesmos foram irradiados seguindo a simulação do planejamento escolhido e utilizando um objeto simulador de PMMA produzido para medidas de VMAT. Essa irradiação teve como finalidade verificar através das duas técnicas de dosimetria as curvas de isodose dessa simulação de tratamento. Todos os tipos de dosímetros apresentaram resultados satisfatórios na verificação das curvas de isodose utilizando ambas as técnicas de dosimetria. Porém, analisando a complexidade das curvas de isodose e a possibilidade das curvas estarem muito próximas, o microdosímetro de LiF:Mg,Ti se mostrou o mais apropriado para o uso devido à suas pequenas dimensões. Em relação à melhor técnica, como ambas apresentaram resultados satisfatórios, a técnica TL é a que apresenta menor complexidade em ser utilizada, pois a maioria dos Departamentos de Radioterapia já possuem um Laboratório para leitura TL. A técnica OSL exige mais cuidados e maior investimento do Departamento.
Title in English
Application of the thermoluminescent (TL) and optically stimulated luminescence (OSL) dosimetry techniques to determinate the isodose curves in a cancer treatment planning simulation using volumetric modulated arc therapy - VMAT
Keywords in English
dosimetry
isodose curves
optically stimulated luminescence
thermoluminescence
volumetric modulated arc therapy
Abstract in English
The Volumetric Modulated Arc Therapy (VMAT) is an advance technique of Intensity Modulated Radiation Therapy (IMRT). This progress is due to the continuous gantry rotation with the radiation beam modulation providing lower time of the patient treatment. This research aimed the verification of the isodose curves in a simulation of a vertebra treatment with spinal cord protection using the thermoluminescent (TL) and optically stimulated luminescence (OSL) dosimetry techniques and theLiF:Mg,Ti (TLD-100), CaSO4:Dy and Al2O3:C dosimeters and LiF:Mg,Ti microdosimeters (TLD-100). The dosimeters were characterized using PMMA plates of 30x30x30 cm3 and different thickness. All irradiations were done using Truebeam STx linear accelerator of Hospital Israelita Albert Einstein, with 6 MV photons beam. After the dosimeter characterization, they were irradiated according the specific planning simulation and using a PMMA phantom developed to VMAT measurements. This irradiation aimed to verify the isodose curves of the treatment simulation using the two dosimetry techniques. All types of dosimeters showed satisfactory results to determine the dose distribution but analysing the complexity of the isodose curves and the proximity of them, the LiF:Mg,Ti microdosimeter showed the most appropriate for use due to its small dimensions. Regarding the best technique, as both technique showed satisfactory results, the TL technique presents less complex to be used because the most of the radiotherapy departments already have a TL laboratory. The OSL technique requires more care and greater investment in the hospital.
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.
Publishing Date
2015-08-07
 
WARNING: Learn what derived works are clicking here.
All rights of the thesis/dissertation are from the authors
CeTI-SC/STI
Digital Library of Theses and Dissertations of USP. Copyright © 2001-2024. All rights reserved.