Nom complet
Barbara Szot Marczewski
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
São Paulo, 2006
Directeur
Jury
Osso Júnior, João Alberto (Président)
Araújo, Elaine Bortoleti de
Guimaraes, Maria Ines Calil Cury
Herdade, Silvio Bruni
Silva, Constancia Pagano Goncalves da
Titre en portugais
Estudos de marcação do etidronato com 188Re proveniente de diferentes geradores de 188W/ 188Re
Mots-clés en portugais
etidronato
gerador
HEDP
radiomarcacao
renio-188
Resumé en portugais
O interesse pelo 188Re para aplicações terapêuticas na medicina nuclear é devido à meia-vida de 16,9 horas, emissão de partículas βֿ com energia máxima de 2,12 MeV e raios-γ de 155 keV adequados para a aquisição de imagens. O estudo apresenta a radiomarcação do HEDP (etidronato) com o 188Re eluído de geradores de 188W/188Re a base de Al2O3 e tipo-gel 188WZr. A dependência do rendimento do 188Re-HEDP na concentração do agente redutor, pH, tempo de reação, temperatura e adição de carregador Re2O7 foram avaliados. A partir das condições ótimas de marcação os rendimentos do 188Re-HEDP foram ≥ 98% tanto para os kits líquidos como liofilizados. A formulação padrão que representou esses resultados contém: 30 mg de HEDP, 7 mg de SnCl2, 3 mg de ácido ascórbico e adição de 20 μg de Re2O7. As reações foram conduzidas sob aquecimento de 100 °C por 30 minutos, seguidos de 60 minutos de incubação. Outro aspecto importante do trabalho foi o controle de qualidade radioquímico, comparando os resultados de CP, CCD e cromatografia iônica, além dos experimentos com a CLAE. A distribuição biológica realizada comprovou a captação pelo esqueleto e a estabilidade in vivo dos complexos de 188Re-HEDP.
Titre en anglais
Studies of HEDP labelled with 188Re from different generators of 188W / 188Re.
Mots-clés en anglais
generators
labelled
radiollabeling
rhenium-188
Resumé en anglais
The widespread interest in 188Re for therapeutic applications, is due to its attractive 16,9 hours half-life, emission of a βֿ particle with maximum energy of 2.12 MeV and gama-ray of 155 keV suitable for imaging. This work presents the radiollabeling of HEDP (etidronate) with 188Re eluted from alumina-based 188W/188Re generators and tungstate-based 188W/188Re gel generators. Dependence of the yield of the 188Re-HEDP on the concentration of the reduction agent, pH, reaction time, temperature and addition of carrier Re2O7 were evaluated. The radiollabeling of 188Re-HEDP procedure using the optimum conditions resulted a yield ≥ 98% for liquid and lyophilized kits. This basic formulation contains: 30 mg de HEDP, 7 mg de SnCl2, 3 mg de ascorbic acid and addition of 20 μg of Re2O7. The reactions were carried out with heating in boiling water for 30 minutes followed by 60 minutes of incubation. Another important aspect of this work was the radiochemical quality control compairing the results of PC, TLC and ion chromatography, along with the experiments with HPLC. The biological distribution proved the adequate bone uptake and in vivo stability of 188Re-HEDP complexes.
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
Date de Publication
2007-06-22
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.