• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Mémoire de Maîtrise
DOI
https://doi.org/10.11606/D.85.2000.tde-29102003-105733
Document
Auteur
Nom complet
Ary de Araujo Rodrigues Junior
Adresse Mail
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
São Paulo, 2000
Directeur
Jury
Caldas, Linda Viola Ehlin (Président)
Mastro, Nélida Lúcia Del
Vizeu, Dirceu Martins
Titre en portugais
VIDRO COMERCIAL COMO DETECTOR E MEDIDOR DE RADIAÇÃO NUM IRRADIADOR DE GRANDE PORTE.
Mots-clés en portugais
cobalto-60
detector de radiação
dose alta
dosimetria
dosímetro
irradiador gama
radiação gama
vidro
Resumé en portugais
Amostras de vidro comercial para janelas de fabricação nacional foram testadas como dosímetros de rotina para doses altas em um irradiador de grande porte que utiliza uma fonte de Co-60. Estas amostras foram estudadas em termos da uniformidade do lote, repetibilidade, desvanecimento, resposta à dose absorvida entre 5 e 30 kGy, de processamentos rotineiros. A técnica da absorção óptica foi usada para medir-se as amostras de vidro. Todos os resultados obtidos mostram a viabilidade do uso de amostras de placas de vidro para janelas como um sistema dosimétrico de rotina, assim como indicador de irradiação Sim/Não para doses altas em irradiadores de grande porte que utilizam fontes de Co-60
Titre en anglais
COMMERCIAL PLATE WINDOW GLASS AS DETECTOR AND RADIATION METER AT A TOTE BOX IRRADIATOR
Mots-clés en anglais
cobalt-60
dosimeter
dosimetry
gamma irradiator
gamma radiation
glass
high doses
radiation detector
Resumé en anglais
Commercial window glass samples were tested as routine high dose dosimeters at a Co-60 tote box irradiator. These samples were studied in terms of their batch uniformity, response repeatibility, fading and absorbed dose response from 5 until 30 kGy in typical irradiation procedures. The optical absorption technique was used to measure the glass samples. All the obtained results show the feasibility of using plate window glass samples as a routine high dose dosimetry system and as a Yes/No irradiation indicator for a Co-60 tote box irradiator.
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
arydis.pdf (1.28 Mbytes)
Date de Publication
2004-02-19
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.