Mémoire de Maîtrise
DOI
https://doi.org/10.11606/D.85.2009.tde-29062009-153847
Document
Auteur
Nom complet
Osvaldo Luiz da Costa
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
São Paulo, 2009
Directeur
Jury
Sciani, Valdir (Président)
Santos, Gonçalo Rodrigues dos
Sumiya, Luiz Carlos do Amaral
Titre en portugais
Otimização do sistema de carga e descarga no porta-alvo de irradiação  de H218O utilizando a produção de 18F- no Cíclotron Cyclone 30 do IPEN-CNEN/SP
Mots-clés en portugais
cíclotron
FDG
flúor
PET
Resumé en portugais
O aumento da demanda no Brasil pelo radiofármaco [18F]FDG para exames de tomografia por emissão de pósitron (PET-CT) e sua meia-vida de 109,7 minutos exigem uma atenção especial para a cadeia produtiva deste radiofármaco. Desde a irradiação da água enriquecida em 18O até a passagem do paciente pelo tomógrafo, numa seqüência de procedimentos que pode durar até cerca de seis horas, todas as etapas da cadeia produtiva devem ter a maior confiabilidade possível, pois qualquer falha em uma das etapas será sentida na extremidade da cadeia produtiva. A falta de indicação de posição da válvula do Sistema de Carga e Descarga do Porta-alvo de 18F- no Centro de Aceleradores Cíclotron levou a perda de produção de 18F-, contaminação da Sala de Irradiação e aumento da dose dos trabalhadores envolvidos na operação e manutenção dos sistemas de irradiação. Este trabalho testou o comportamento de três tipos de sensores de posição (microswitch, reedswitch e sensor de proximidade indutivo) no ambiente da Sala de Irradiação 1.2 do Centro de Aceleradores Cíclotron, que está sujeito a altas taxas de radiação gama e nêutrons devido à produção rotineira de 18F- e 123I, através deste teste foi possível encontrar o sensor de posição mais adequado para trabalhar no porta-alvo de 18F-, e através da reprogramação do controlador lógico programável, foi possível evitar este tipo de falha durante a produção de 18F- no Centro de Aceleradores Cíclotron, e aumentar a confiabilidade na cadeia produtiva do [18F]FDG.
Titre en anglais
LOAD AND UNLOAD SYSTEM OPTIMIZATION ON H2 18O IRRADIATION TARGET USED FOR 18F- PRODUCTION AT THE CYCLOTRON CYCLONE 30 FROM IPEN-CNEN/SP
Mots-clés en anglais
cíclotron
FDG
flúor
PET
Resumé en anglais
The demand growing in Brazil by the radiopharmaceutical [18F]FDG in positron emission tomography (PET-CT) and the 109,7 minutes half life claim special attention to the productive chain of this radiopharmaceutical. Since the [18O]water irradiation until the tomograph patient scanning, in sequential procedures that may spent about six hours, all the productive chain stages must be as reliable as possible, because any stage failed will be perceived in productive chain extremity. The position indication absence from Load and Unload 18F- Target System valve in Cyclotron Accelerators Center resulted in 18F- production loss, Irradiation Room contamination and the increase workers dose responsible by operation and maintenance of irradiation systems. This study tested the behaviour of three types of position sensors (microswitch, reedswitch and inductive sensor), into Irradiation Room 1.2 environment of the Cyclotron Accelerators Center, where there are high gamma radiation and neutrons rates because the routine 18F- and 123I production, through this test was possible to discover the fitter position sensor to run on 18F- Target, and after rewriting the programmable logic controller software was possible avoid this type of fail at 18F- production time in Cyclotron Accelerators Center, and to grow up the reliability on [18F]FDG productive chain.
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
Date de Publication
2009-07-16
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.