Tese de Doutorado
DOI
https://doi.org/10.11606/T.85.2007.tde-27112007-144824
Documento
Autor
Nome completo
Maria Esmeralda Ramos Poli
E-mail
Unidade da USP
Área do Conhecimento
Data de Defesa
Imprenta
São Paulo, 2007
Orientador
Banca examinadora
Rodrigues, Letícia Lucente Campos (Presidente)
Furquim, Tânia Aparecida Correia
Ghilardi Netto, Thomaz
Rocha, Felícia Del Gallo
Rodrigues, Laura Natal
Título em português
Definição do volume de planejamento do alvo (PTV) e seu efeito na radioterapia
Palavras-chave em português
Movimento de Órgãos
PTV
Radioterapia
Volume alvo
Resumo em português
Este trabalho visa estudar as margens necessárias para definir o volume de planejamento do alvo (PTV) requeridas para tratar adequadamente tumores móveis como os localizados na próstata ou tumores localizados em áreas com pouca mobilidade como os da região da cabeça e pescoço, na ausência de localização do alvo por imagem. Também tem como objetivo avaliar o impacto causado pelo PTV, em termos de dose, nas estruturas críticas ao seu redor e sua influência quando planejamento inverso é utilizado na radioterapia com modulação de feixe (IMRT). Dados de 387 pacientes de próstata foram analizados retrospectivamente. Todos os pacientes receberam localização pré-tratamento com ultra-som 2D resultando em 10.327 localizações, cada uma com deslocamento de isocentro em três direções: antero-posterior (AP), lateral direitaesquerda (DE), e superior-inferior (SI). O deslocamento médio e desvio padrão (SD) para cada direção foi estimado a partir dos dados de tratamento gravados diariamente. As incertezas (SD) na posição do alvo foram 4,4 mm (AP), 3,6 mm (DE), e 4,5 mm (SI). O estudo das incertezas no posicionamento diário de 78 pacientes com tumores de cabeça e pescoço que utilizaram máscaras termoplásticas como imobilizadores, avaliados com equipamento de portal com imagem eletrônica (EPID), mostrou variações (SD) na posição do isocentro de tratamento de 3,1 mm (AP), 1,5 mm (DE), 4,5 mm (SI). Aplicando estes desvios num simulador antropomórfico estudou-se os histogramas de dose-volume resultantes do deslocamento do isocentro no tratamento diário. Os resultados mostraram a importância de se colocar margens no volume clínico do alvo para garantir um tratamento adequado e também mostraram que a variação diária do isocentro de tratamento pode causar um aumento de dose maior que o nível de tolerância dos órgãos críticos.
Título em inglês
Planning target volume (PTV) definition and its effects in the radiotherapy
Palavras-chave em inglês
Organs mobile
PTV
Radiotherapy
Target volume
Resumo em inglês
This work intends to study the margins required to define a planning target volume (PTV) for adequate treatment of the mobile tumors such as prostate or those located in areas with less mobility as the ones in head and neck region, in the absence of daily localization imaging based. It is also intends to evaluate the impact caused by the PTV, in terms of dose, to the critical structures surrounding the PTV and its influence when inverse planning is used in the intensity-modulated radiation therapy (IMRT). Data from 387 prostate patients were analyzed retrospectively. Every patient in the study received daily pre-treatment localization with 2D ultrasound resulting in a total of 10,327 localizations, each comprising of an isocenter displacement in 3 directions: anterior-posterior (AP), right-left lateral (RL), and superior-inferior (SI). The mean displacement and standard deviation (SD) for each direction for each patient was computed from daily treatment records. The uncertainties (SD) in the target position were 4.4 mm (AP), 3.6 mm (RL), and 4.5 mm (SI). A study of the uncertainties in the daily positioning of 78 head and neck patients who used thermoplastic mask to immobilize them, evaluated with electronic portal imaging device (EPID), showed variations (SD) in the isocenter treatment position of 3.1 mm (AP), 1.5 mm (RL), and 4.5 mm (SI). By applying these shifts in an anthropomorphic phantom it was studied the dose-volume histograms resultant of the isocenter displacement in the daily treatment. The result showed the importance of putting margins in the clinical target volume to assure an adequate treatment and also showed that isocenter daily variation can cause an increase to the dose greater than the tolerance level to the critical organs.
 
AVISO - A consulta a este documento fica condicionada na aceitação das seguintes condições de uso:
Este trabalho é somente para uso privado de atividades de pesquisa e ensino. Não é autorizada sua reprodução para quaisquer fins lucrativos. Esta reserva de direitos abrange a todos os dados do documento bem como seu conteúdo. Na utilização ou citação de partes do documento é obrigatório mencionar nome da pessoa autora do trabalho.
Data de Publicação
2007-12-10
 
AVISO: Saiba o que são os trabalhos decorrentes clicando aqui.
Todos os direitos da tese/dissertação são de seus autores
CeTI-SC/STI
Biblioteca Digital de Teses e Dissertações da USP. Copyright © 2001-2024. Todos os direitos reservados.