• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Disertación de Maestría
DOI
https://doi.org/10.11606/D.85.2016.tde-27062016-144119
Documento
Autor
Nombre completo
Júlio Batista Rodrigues da Silva
Dirección Electrónica
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
São Paulo, 2016
Director
Tribunal
Costa, Fábio Eduardo da (Presidente)
Mesquita, Carlos Henrique de
Oliveira, Cristiano Luis Pinto de
Título en portugués
Fabricação e caracterização de detector de Barreira de superfície a partir de substrato de silício comercial
Palabras clave en portugués
detectores de radiação
semicondutores
silício
Resumen en portugués
Neste trabalho foram desenvolvidos detectores de radiação Barreira de superfície de silício que fossem capazes de detectar a presença da radiação gama de baixa energia proveniente de sementes de iodo-125 utilizada em tratamentos de braquiterapia. A partir de substratos comerciais de silício foram desenvolvidos os detectores, de uma sequência que partiu de tratamentos químicos nas superfícies destes substratos com a intenção de minimizar os possíveis ruídos gerados, validação das amostras obtidas como diodos, assegurando características detectoras, e a efetiva utilização como detector para fontes radioativas de iodo-125 com energia em torno de 25 kev e amerício-251 com energia na ordem de 59 kev. Finalizou realizando a análise dos espectros de energia obtidos e assim foi possível observar a capacidade destes detectores para mensuração da energia proveniente destas sementes.
Título en inglés
Fabrication and characterization of surface barrier detector from commercial silicon substrate
Palabras clave en inglés
radiation detectors
semiconductors
silicon
Resumen en inglés
In this work it was developed radiation detectors silicon surface barrier that were capable of detecting the presence of gamma radiation from a low energy of iodine-125 seeds used in brachytherapy treatments. From commercial silicon substrates detectors were developed, one sequence left of chemical treatments to the surfaces of these substrates with the intention of minimizing the possible noise generated, validation of the samples obtained as diodes, ensuring detector characteristics and effective use as detector for iodine-125 radioactive sources with energy of about 25 kev and americium-251 with energy on the order of 59 kev. Finished performing the analysis of the obtained energy spectra and so it was possible to observe the ability of these detectors to measure the energy from these seeds.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Fecha de Publicación
2016-07-01
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.