• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Mémoire de Maîtrise
DOI
https://doi.org/10.11606/D.85.2011.tde-25082011-105058
Document
Auteur
Nom complet
Talita Sabino
Adresse Mail
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
São Paulo, 2011
Directeur
Jury
Rodrigues, Laura Natal (Président)
Giordani, Adelmo Jose
Rodrigues Junior, Orlando
Titre en portugais
Estudo e validação da dosimetria em condições de não-referência
Mots-clés en portugais
campos pequenos
detector diamante
dosimetria de não-referência
Resumé en portugais
Com o avanço tecnológico dos equipamentos utilizados em radioterapia tornaram-se possíveis o uso de alguns campos de radiação nomeados como campos pequenos em algumas modalidades especiais de radioterapia. Com isso, a dosimetria dos feixes de radiação também teve de ser revista, pois com estes novos tamanhos de campos, não há condição de referência como aquela dita nos protocolos e diretrizes de dosimetria. Neste trabalho foi realizado um estudo completo sobre os campos pequenos, bem como sua dosimetria, mostrando o comportamento dos detectores nessa nova condição de dosimetria através de uma comparação entre os detectores utilizados e dados já publicados na literatura. Além disso, os dados obtidos experimentalmente puderam ser validados através de comparação com dados publicados por outros autores. Na caracterização do detector de diamante o mesmo apresentou-se apropriado em todos os parâmetros para medidas com campos pequenos. Na análise do fator de qualidade Q os resultados experimentais obtidos nesta investigação mostraram diferenças percentuais de 1,8%; 4,0% e 4,9% para câmara do tipo CC01, CC13 e diodo estereotáxico respectivamente. Na avaliação de PDP e TMR foi possível observar a dificuldade nas medições com campos pequenos bem como na comparação de diferentes detectores, para PDP a maior diferença foi de 2,6% e para TMR 2,7%.
Titre en anglais
Estudy and validation of dosimetry in non-reference conditions
Mots-clés en anglais
diamond detector
nonequilibrium dosimetry
small fields
Resumé en anglais
With the technological equipment used in radiotherapy became possible use of some radiation fields named small fields in some special forms of radiotherapy. Thus, the dosimetry of radiation fields also had to be revised, as with these new sizes of fields, there is no reference condition such as that expressed in dosimetry protocols and guidelines. This work represents a complete study of small fields and its dosimetry, showing the behavior of the detectors in this new condition of dosimetry through a comparison between the detectors used and data already published. Moreover, the experimental data can be validated by comparison with data published by others authors. In the characterization of the same diamond detector has been considered appropriate in all parameters measured with small fields. The analysis of the beam quality factor (Q) the experimental results obtained in this study showed differences in percentages of 1.8%, 4.0% and 4.9% for chamber-type CC01, CC13 and stereotactic diode respectively. In evaluating PDP and TMR was possible to observe the difficulty in measurements with small fields and the comparison of different detectors, the biggest difference for PDP was 2.6% and 2.7% for TMR.
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
2011SabinoEstudo.pdf (1.89 Mbytes)
Date de Publication
2011-08-31
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.