Master's Dissertation
DOI
https://doi.org/10.11606/D.85.2011.tde-25082011-105058
Document
Author
Full name
Talita Sabino
E-mail
Institute/School/College
Knowledge Area
Date of Defense
Published
São Paulo, 2011
Supervisor
Committee
Rodrigues, Laura Natal (President)
Giordani, Adelmo Jose
Rodrigues Junior, Orlando
Title in Portuguese
Estudo e validação da dosimetria em condições de não-referência
Keywords in Portuguese
campos pequenos
detector diamante
dosimetria de não-referência
Abstract in Portuguese
Com o avanço tecnológico dos equipamentos utilizados em radioterapia tornaram-se possíveis o uso de alguns campos de radiação nomeados como campos pequenos em algumas modalidades especiais de radioterapia. Com isso, a dosimetria dos feixes de radiação também teve de ser revista, pois com estes novos tamanhos de campos, não há condição de referência como aquela dita nos protocolos e diretrizes de dosimetria. Neste trabalho foi realizado um estudo completo sobre os campos pequenos, bem como sua dosimetria, mostrando o comportamento dos detectores nessa nova condição de dosimetria através de uma comparação entre os detectores utilizados e dados já publicados na literatura. Além disso, os dados obtidos experimentalmente puderam ser validados através de comparação com dados publicados por outros autores. Na caracterização do detector de diamante o mesmo apresentou-se apropriado em todos os parâmetros para medidas com campos pequenos. Na análise do fator de qualidade Q os resultados experimentais obtidos nesta investigação mostraram diferenças percentuais de 1,8%; 4,0% e 4,9% para câmara do tipo CC01, CC13 e diodo estereotáxico respectivamente. Na avaliação de PDP e TMR foi possível observar a dificuldade nas medições com campos pequenos bem como na comparação de diferentes detectores, para PDP a maior diferença foi de 2,6% e para TMR 2,7%.
Title in English
Estudy and validation of dosimetry in non-reference conditions
Keywords in English
diamond detector
nonequilibrium dosimetry
small fields
Abstract in English
With the technological equipment used in radiotherapy became possible use of some radiation fields named small fields in some special forms of radiotherapy. Thus, the dosimetry of radiation fields also had to be revised, as with these new sizes of fields, there is no reference condition such as that expressed in dosimetry protocols and guidelines. This work represents a complete study of small fields and its dosimetry, showing the behavior of the detectors in this new condition of dosimetry through a comparison between the detectors used and data already published. Moreover, the experimental data can be validated by comparison with data published by others authors. In the characterization of the same diamond detector has been considered appropriate in all parameters measured with small fields. The analysis of the beam quality factor (Q) the experimental results obtained in this study showed differences in percentages of 1.8%, 4.0% and 4.9% for chamber-type CC01, CC13 and stereotactic diode respectively. In evaluating PDP and TMR was possible to observe the difficulty in measurements with small fields and the comparison of different detectors, the biggest difference for PDP was 2.6% and 2.7% for TMR.
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.
2011SabinoEstudo.pdf (1.89 Mbytes)
Publishing Date
2011-08-31
 
WARNING: Learn what derived works are clicking here.