• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Disertación de Maestría
DOI
https://doi.org/10.11606/D.85.2017.tde-24072017-152855
Documento
Autor
Nombre completo
Lilian Toshie Kuahara
Dirección Electrónica
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
São Paulo, 2017
Director
Tribunal
Potiens, Maria da Penha Albuquerque (Presidente)
Daros, Kellen Adriana Curci
Rocha, Felícia Del Gallo
Título en portugués
Desenvolvimento de uma metodologia de calibração "in situ " de medidores de atividade
Palabras clave en portugués
ativímetro
calibração
controle de qualidade
Resumen en portugués
O desempenho de uma prática segura e eficiente de um serviço de medicina nuclear depende, entre outros fatores, de um programa de controle de qualidade completo, principalmente em se tratando dos instrumentos medidores de atividade dos radionuclídeos, os ativímetros. Um programa de controle de qualidade completo deve incluir a calibração de todos os instrumentos de medição utilizados no procedimento. No entanto, no Brasil, a atual norma que estabelece os requisitos de proteção radiológica para serviços de medicina nuclear (SMN), não inclui, ainda, a calibração do ativímetro. Considerando que estes instrumentos, por diversas razões, são de difícil remoção para envio a um serviço de calibração, o propósito deste trabalho foi desenvolver uma metodologia de calibração de medidores de atividades que possa ser aplicada "in situ", para o principal radiofármaco utilizado atualmente, o 99mTc. Foram definidos os parâmetros de influência que devem ser levados em conta durante a calibração, assim como uma logística de transporte dos radiofármacos. Um programa de controle de qualidade foi aplicado aos ativímetros do Laboratório de Calibração de Instrumento (LCI). Neste trabalho foram desenvolvidas três metodologias diferentes de calibração, considerando a logística disponível e também a origem da fonte de referência. Na primeira metodologia poderá ser aplicada nos casos em que o LCI envia uma fonte de referência ao SMN. Na segunda o SMN envia uma fonte previamente medida ao LCI que determinará sua atividade real. A terceira metodologia foi aplicada para calibração dos ativímetros pertencentes ao setor de produção de radiofármacos do IPEN. Neste caso a fonte de referência foi enviada ao LCI após uma medição prévia pelo setor de produção. Foi possível aplicar as metodologias em alguns instrumentos pertencentes a clínicas e ao setor de produção. Em todos eles foram encontrados coeficientes de calibração diferentes entre si. A maior variação encontrada foi de 5%, indicando que a medição com este ativímetro está menor em 5% do que é necessário aplicar no paciente. Verificou-se que a troca de recipientes deixa um resíduo que não tem sido considerado nas medições clínicas, podendo acrescentar uma diferença de até 3% nas medições.
Título en inglés
Development of an "in situ" calibration methodology to activity meters
Palabras clave en inglés
activimeter
calibration
quality control
Resumen en inglés
The performance of a safety and efficient practice of a nuclear medicine service depends, among other factors, on a complete quality control program, especially in the case of the radionuclide activity measuring instrument, the activimeter. A complete quality control program should include the calibration of all measurement instruments used in the procedure. However, in Brazil, the actual standard that establishes the requirements of radiological protection for nuclear medicine services (NMS), does not include the calibration of the activimeter. Considering that these instruments, for various reasons, are difficult to remove for sending to a Calibration Service, the purpose of this work is to develop a methodology for activimeter calibration that can be applied "in situ" to the most used radiopharmaceutical, 99mTc. The parameters of influence that should be taken in into account during the calibration were defined, as well as a transport logistics of the radiopharmaceuticals. A quality control program was applied to LCI activimeters. In this study, three calibration methodologies have been established, considering the available logistics and the reference source origin. The first can be applied in cases that LCI sends the reference sample to the NMS. In the second, the NMS sends an already measured sample to the LCI that will determine its real activity. The third methodology was developed to be applied to the activimeters belonging to the radiopharmaceutical sector of IPEN. In this case, the reference source was sent to the LCI after a previous measurement by the production sector. It was possible to apply the methodologies in some instruments belonging to clinics and the production sector. In all of them, different calibration coefficients were found. The largest variation found was 5%, indicating that the measurement with this activimeter is 5% lower than that required for the patient. It was found that the exchange of containers leaves a residue that has not been considered in clinical measurements, and may add a difference of up to 3% in the measurements.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Fecha de Publicación
2017-08-10
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.