Título en portugués
Estudo e otimização dos parâmetros de processamento por radiação gama em escala industrial considerando fatores operacionais
Palabras clave en portugués
cobalto-60
dosimetria
irradiação gama
irradiador industrial
mapeamento dosimétrico
Resumen en portugués
O processamento por radiação gama para beneficiamento de produtos tem se tornado uma tecnologia aceita mundialmente. Tem como aplicações a esterilização de produtos médicos, a irradiação de alimentos e produtos agrícolas, a modificação de materiais poliméricos e biomateriais, a preservação de objetos de patrimônio cultural, a esterilização de tecidos humanos para transplante, a mudança de cor em gemas, dentre outros. Desde 2004, o Irradiador Multipropósito de Cobalto-60 do Centro de Tecnologia das Radiações do IPEN tem sido utilizado no estudo e aperfeiçoamento dessas aplicações com objetivos de pesquisa e no estabelecimento de aplicações rotineiras. Este, embora concebido para trabalhar no modo contínuo de irradiação, é utilizado no modo estacionário mais indicado para irradiações de materiais delicados ou de pesquisa. Neste trabalho foram validadas e verificadas experimentalmente as adequações dos métodos à irradiação estacionária; bem como as interrupções para medição de doses em dosímetros de polimetilmetacrilato em processos fracionados, onde seu uso se mostrou adequado para taxas de dose maiores que 2kGy·h-1. A descrição do processo de carga das fontes mostra a importância do seu planejamento e seu impacto na distribuição de taxas de dose. Os mapeamentos das doses e taxas de dose permitiram localizar regiões de valores homogêneos e máximos. Foi estabelecido um procedimento de irradiação de tecidos para aloenxertia utilizando monitoração dosimétrica externa. Foram levantados os custos e despesas de irradiação, aplicáveis a instalações governamentais. O balanço energético da piscina de armazenamento das fontes permitiu calcular o fluxo de calor do sistema e definir as condições máximas de operação sem trocador de calor.
Título en inglés
Study and optimization of parameters of gamma ray processing in industrial scale considering operational factors
Palabras clave en inglés
cobalt-60
dose mapping
dosimetry
gamma irradiation
industrial irradiation
Resumen en inglés
The gamma radiation processing is a well-accepted technology around the world. The mean applications are sterilization of medical products, irradiation of food and agriculture products, polymeric and biomaterials modification, Cultural Heritage objects preservation, humans tissues sterilization, gemstone colorization. Since 2004, the Multipurpose Gamma Irradiation Facility at the Radiation Technology Center of the Nuclear and Energy Research Institute has been used for improvement of research applications and for establishment of routine processes. Moreover, this equipment was developed to work in continuous irradiation mode; it has been used in stationary irradiation mode most of times - recommended to the irradiation of sensible materials. In this work, the applicability of the stationary irradiation methods were experimentally validated and verified. Results shown that absorbed dose measurements carried out with polymethyl methacrylate dosimeters in irradiation processes with interruption can be performed at dose rates upper 2kGy·h-1. Radioactive sources loading and installation processes have been documented showing the importance of planning, as well the impact in the dose rates distribution at the source racks. The dose and dose rate mapping allowed finding homogeneous and higher dose rates zones. A procedure for human tissues irradiation using only external dosimetry was established. The irradiation service costs and expenses related have been estimated, applicable particularly for government facilities. The energetic balance of the sources storage pool was carry out to evaluate the heat transfer conditions and limitations of the system.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.