Doctoral Thesis
DOI
https://doi.org/10.11606/T.85.2015.tde-23102015-094126
Document
Author
Full name
Osvaldo Luiz da Costa
E-mail
Institute/School/College
Knowledge Area
Date of Defense
Published
São Paulo, 2015
Supervisor
Committee
Rostelato, Maria Elisa Chuery Martins (President)
Araki, Koiti
Sene, Frank Ferrer
Sumiya, Luiz Carlos do Amaral
Zeituni, Carlos Alberto
Title in Portuguese
Estudo e desenvolvimento de uma nova metodologia de produção de iodo-125 a partir de xenônio-124 pelo método de ativação neutrônica
Keywords in Portuguese
braquiterapia
iodo-125
iodo-126
produção
xenônio-124
Abstract in Portuguese
Neste trabalho foi desenvolvida uma nova metodologia de produção de iodo-125, que resultou na primeira produção deste radionuclídeo no Brasil. Cápsulas de alumínio foram projetadas, fabricadas e avaliadas para que suportassem condições de pressão, temperatura e fluxo de nêutrons no reator nuclear IEA-R1 do IPEN sem a ocorrência de liberação de material radioativo. Foram projetados, desenvolvidos e fabricados sistemas de carregamento, descarregamento e recuperação dos gases para a manipulação do gás xenônio e do iodo. Foi desenvolvido um novo método de lavagem da cápsula, para dissolução do iodo-125 adsorvido nas paredes, por meio de imersão em banho ultrassônico. Foram irradiadas três cápsulas no reator nuclear IEA-R1, por um período de aproximadamente 60 h contínuas, a um fluxo de nêutrons de 5,5 x 1013 n cm-2 s-1. Foi produzido um total de 13,53 GBq (365,73 mCi) de iodo-125, e o único contaminante encontrado foi o radionuclídeo iodo-126. Na análise radioquímica, pelo método de cromatografia em papel ascendente, o iodo-125 em solução de NaOH apresentou percentual de iodeto acima de 98%, superior à exigência da farmacopeia americana para soluções de iodo radioativo que é de 95%. Para a análise radionuclídica foi desenvolvida uma fonte planar, a base de resina epoxídica, para a contagem do iodo-125 em detector de germânio de alta pureza. A correlação entre o iodo-125 e o iodo-126 produzido apresentou valores entre 0,5 e 0,7% após um período de decaimento de 10 d, grau de pureza suficiente para a utilização em técnicas de radioimunoensaio.
Title in English
Study and development of a new methodology for production of iodine-125 from xenon-124 through the method of neutron activation
Keywords in English
brachytherapy
iodine-125
iodine-126
production
xenon-124
Abstract in English
A new methodology of iodine-125 production was developed in this work, performing the first production of iodine-125 in Brazil. Aluminium capsules were designed, manufactured and evaluated to support condition as pressure, temperature and neutron flux in IEA-R1 Nuclear Reactor without releasing radioactive material into reactor pool. It was designed, developed and manufactured systems to load, unload and recover gases to manipulate the xenon gas and the iodine. A new method of capsule rinsing was developed, to dissolve the iodine-125 adsorbed in the walls, using immersion in ultrasonic bath. Three capsules were irradiated in IEA-R1 Nuclear Reactor for approximately 60 h continuous, at a neutron flux of 5.5 x 1013 n cm-2 s-1. It was produced a total of 13.53 GBq (365.73 mCi) of iodine-125 and the radionuclide iodine-126 was the only contaminant found. In radiochemical analysis, by ascending paper chromatography method, the iodine-125 in NaOH solution presented a percentage over 98%, higher than American pharmacopeia requirements for iodine radioactive solutions which is 95%. A planar source was developed, based on epoxy resin, to iodine-125 radionuclidic analysis in high purity germanium detector. The correlation between iodine-125 and iodine-126 produced showed values between 0.5 and 0.7% after a 10 d decay period, a purity grade enough to apply in radioimmunoassay techniques.
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.
2015CostaEstudo.pdf (18.97 Mbytes)
Publishing Date
2015-10-28
 
WARNING: Learn what derived works are clicking here.
All rights of the thesis/dissertation are from the authors
CeTI-SC/STI