Dissertação de Mestrado
DOI
https://doi.org/10.11606/D.85.2001.tde-23072002-091706
Documento
Autor
Nome completo
Patricia Lammoglia
E-mail
Unidade da USP
Área do Conhecimento
Data de Defesa
Imprenta
São Paulo, 2001
Orientador
Banca examinadora
Caldas, Linda Viola Ehlin (Presidente)
Medeiros, Regina Bitelli
Terini, Ricardo Andrade
Título em português
"Elaboração e Implementação de Testes de Controle de Qualidade em Equipamentos de Angiografia por Subtração Digital"
Palavras-chave em português
Angiografia
Controle de Qualidade
Fluoroscopia
Garantia de Qualidade
Resumo em português
Foram elaborados e implementados testes de controle de qualidade em equipamentos de angiografia por subtração digital. Estes testes foram baseados em normas nacionais e internacionais e foram implementados em cinco equipamentos de três instituições diferentes. Estes testes avaliam os parâmetros de desempenho dos equipamentos e são utilizados para a determinação da taxa de kerma no ar na entrada da pele do paciente e do corpo clínico. Os testes foram realizados utilizando dispositivos, simuladores de pacientes e câmaras de ionização. Os testes convencionais e do sistema de subtração digital indicaram que os equipamentos avaliados encontravam-se em bom estado de desempenho. Os testes para verificação da taxa de kerma no ar indicaram que um dos equipamentos avaliados apresentou altas taxas de kerma no ar na entrada da pele do paciente em modo fluoroscopia. Este problema foi notificado, e as devidas providências foram imediatamente tomadas pela gerência do hospital.
Título em inglês
Elaboration and Implementation of Quality Control Tests in Digital Subtraction Angiography Equipments
Palavras-chave em inglês
Angiography
fluoroscopy
Quality Control
Resumo em inglês
Quality control tests were elaborated and implementated in digital subtraction angiography equipments. These tests were elaborated based in national and international standards, and they were implementated in five equipments of three different institutions. These tests are utilized to evaluate the performance of these equipments and to determine the patient entrance and personnel air kerma rates. The tests were performed using test tools, patient phantoms e ionization chambers. The conventional tests and the tests of the digital subtraction systems indicated that the evaluated equipments presented a good performance. The tests implementated to determine the air kerma rates presented, in one case (fluoroscopy equipment), high patient entrance skin air kerma rate. This problem was notified, and the providences were promptly taken by the hospital administration.
 
AVISO - A consulta a este documento fica condicionada na aceitação das seguintes condições de uso:
Este trabalho é somente para uso privado de atividades de pesquisa e ensino. Não é autorizada sua reprodução para quaisquer fins lucrativos. Esta reserva de direitos abrange a todos os dados do documento bem como seu conteúdo. Na utilização ou citação de partes do documento é obrigatório mencionar nome da pessoa autora do trabalho.