• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Mémoire de Maîtrise
DOI
https://doi.org/10.11606/D.85.2017.tde-23062017-100736
Document
Auteur
Nom complet
Daniel Pereira da Silva
Adresse Mail
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
São Paulo, 2017
Directeur
Jury
Moreira, Edson Gonçalves (Président)
Nogueira, Ana Rita de Araujo
Vasconcellos, Marina Beatriz Agostini
Titre en portugais
Otimização da análise por ativação neutrônica instrumental para o estudo de homogeneidade dentro do frasco de materiais de referência de origem marinha
Mots-clés en portugais
elementos traço
estudo de homogeneidade
INAA
material de referência
mexilhão
Resumé en portugais
A utilização de materiais de referência tem sido crescente em laboratórios químicos, uma vez que são importantes para a validação de métodos analíticos. Tais materiais são em geral importados, o que demanda altos investimentos financeiros para adquiri-los, e, portanto, impacta na não utilização dos mesmos por muitos laboratórios nacionais. A certificação de um material de referência é um processo complexo que pressupõe oferecer ao usuário valores atribuídos às propriedades de interesses no material. Neste processo, deve ser realizada a verificação da homogeneidade do material nos frascos. No presente estudo, foi realizado o estudo de homogeneidade dentro do frasco para os elementos K, Mg, Mn, Na e V em dois materiais de referência certificados de origem marinha: o material de referência de mexilhão, produzido no Laboratório de Ativação Neutrônica (LAN) do IPEN - CNEN/SP e o material de referência de tecido de ostra produzido no exterior. Para tanto, os elementos foram determinados por Análise por Ativação Neutrônica Instrumental, com massas variando entre 1 e 250 mg e estimou-se a massa mínima que variou de 0,015 g para Na no material de referência de mexilhão a 0,100 g para V nos dois materiais de referência.
Titre en anglais
Optimization of instrumental neutron activation analysis for the within-bottle homogeneity study of reference materials of marine origin
Mots-clés en anglais
homogeneity study
INAA
mussel
reference material
trace element
Resumé en anglais
The use of reference materials has been increasing in chemical analysis laboratories as its use is important for measurement validation in analytical chemistry. Such materials are generally imported, which require high financial investments in order to acquire them, and therefore it impacts on the difficulty to many national laboratories to use reference materials in their chemical analysis routine. Certification of reference materials is a complex process that assumes that the user is given appropriate assigned values of the properties of interests in the material. In this process, the homogeneity of the material must be checked. In this study, the within-bottle homogeneity study for the elements K, Mg, Mn, Na and V was performed for two reference materials of marine origin: the mussel reference material produced at the Neutron Activation Laboratory (LAN) of IPEN - CNEN/SP and an oyster tissue reference material produced abroad. For this purpose, the elements were determined in subsamples with masses varying between 1 and 250 mg by Instrumental Neutron Activation Analysis (INAA) and minimum sample intakes were estimated, ranging from 0.015 g for Na in the mussel reference material to 0.100 g for V in the two reference materials.
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
Date de Publication
2017-07-13
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.