Disertación de Maestría
DOI
https://doi.org/10.11606/D.85.2015.tde-23032015-081657
Documento
Autor
Nombre completo
Priscila Costa
Dirección Electrónica
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
São Paulo, 2014
Director
Tribunal
Potiens Junior, Ademar José (Presidente)
Koskinas, Marina Fallone
Macacini, José Flávio
Título en portugués
Desenvolvimento de uma metodologia para caracterização do filtro cuno do reator IEA-R1 utilizando o método de Monte Carlo
Palabras clave en portugués
caracterização
filtro cunho
Método de Monte Carlo
rejeito
Resumen en portugués
O filtro cuno faz parte do circuito de tratamento de água do reator IEA-R1 que , quando saturado, é substituído, se tornando um rejeito radioativo que deve ser gerenciado. Neste trabalho foi realizada a caracterização primária do filtro cuno do reator nuclear IEA-R1 do IPEN utilizando-se espectrometria gama associada ao método de Monte Carlo. A espectrometria gama foi realizada utilizando-se um detector de germânio hiperpuro (HPGe). O cristal de germânio representa o volume ativo de detecção do detector HPGe, que possui uma região denominada camada morta ou camada inativa. Na literatura tem sido reportada uma diferença entre os valores experimentais e teóricos na obtenção da curva de eficiência desses detectores. Neste trabalho foi utilizado o código MCNP-4C para a obtenção da calibração em eficiência do detector para a geometria do filtro cuno, onde foram estudadas as influências da camada morta e do efeito de soma em cascata no detector HPGe. As correções dos valores de camada morta foram realizadas variando-se a espessura e o raio do cristal de germânio. O detector possui 75,83 cm3 de volume ativo de detecção, segundo informações fornecidas pelo fabricante. Entretanto os resultados encontrados mostraram que o valor de volume ativo real é menor do que o especificado, onde a camada morta representa 16% do volume total do cristal. A análise do filtro cuno por meio da espectrometria gama, permitiu a identificação de picos de energia. Por meio desses picos foram identificados três radionuclídeos no filtro: 108mAg, 110mAg e 60Co. A partir da calibração em eficiência obtida pelo método de Monte Carlo, o valor de atividade estimado para esses radionuclídeos está na ordem de MBq.
Título en inglés
Development of methodology for characterization of cartridge filters from the IEA-R1 using the Monte Carlo method
Palabras clave en inglés
characterisation
filter cuno
Monte Carlo methods
radioactive waste
Resumen en inglés
The Cuno filter is part of the water processing circuit of the IEA-R1 reactor and, when saturated, it is replaced and becomes a radioactive waste, which must be managed. In this work, the primary characterization of the Cuno filter of the IEA-R1 nuclear reactor at IPEN was carried out using gamma spectrometry associated with the Monte Carlo method. The gamma spectrometry was performed using a hyperpure germanium detector (HPGe). The germanium crystal represents the detection active volume of the HPGe detector, which has a region called dead layer or inactive layer. It has been reported in the literature a difference between the theoretical and experimental values when obtaining the efficiency curve of these detectors. In this study we used the MCNP-4C code to obtain the detector calibration efficiency for the geometry of the Cuno filter, and the influence of the dead layer and the effect of sum in cascade at the HPGe detector were studied. The correction of the dead layer values were made by varying the thickness and the radius of the germanium crystal. The detector has 75.83 cm3 of active volume of detection, according to information provided by the manufacturer. Nevertheless, the results showed that the actual value of active volume is less than the one specified, where the dead layer represents 16% of the total volume of the crystal. A Cuno filter analysis by gamma spectrometry has enabled identifying energy peaks. Using these peaks, three radionuclides were identified in the filter: 108mAg, 110mAg and 60Co. From the calibration efficiency obtained by the Monte Carlo method, the value of activity estimated for these radionuclides is in the order of MBq.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Fecha de Publicación
2015-04-10
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.