Disertación de Maestría
DOI
https://doi.org/10.11606/D.85.2016.tde-20042016-145431
Documento
Autor
Nombre completo
Natália Fiorini da Silva
Dirección Electrónica
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
São Paulo, 2016
Director
Tribunal
Caldas, Linda Viola Ehlin (Presidente)
Medeiros, Regina Bitelli
Vivolo, Vitor
Título en portugués
Estabelecimento de um sistema padrão primário para raios X de energias baixas com uma câmara de ionização de ar livre
Palabras clave en portugués
câmara de ar livre
mamografia
padrão primário
raios X
Resumen en portugués
Neste trabalho foi estabelecido um sistema padrão primário para raios X de energias baixas (10 kV a 50 kV), utilizando uma câmara de ionização de ar livre de cilindros concêntricos da marca Victoreen (modelo 481-5) no Laboratório de Calibração de Instrumentos (LCI) do Instituto de Pesquisas Energéticas e Nucleares (IPEN/CNEN-SP). Para isso foi desenvolvido um novo protocolo de alinhamento da câmara de ionização no sistema de radiação e foi feita uma modificação no suporte dos micrômetros utilizados para o movimento dos cilindros internos. Os resultados obtidos nos testes de estabilidade e de caracterização ficaram dentro dos limites estabelecidos pelas normas IEC 61674 e IEC 60731. Foram determinados também os fatores de correção para atenuação de fótons no ar, transmissão e espalhamento no diafragma, espalhamento e fluorescência, e recombinação iônica. Esses valores foram comparados com os valores obtidos pelo laboratório padrão primário alemão,Physikalisch-Technische Bundesanstalt (PTB), mostrando boa concordância. Por último, foi determinado o valor absoluto da grandeza taxa de kerma no ar para as qualidades padronizadas de mamografia de feixes diretos WMV28 e WMV35 e feixes atenuados WMH28 e WMH35; os resultados são compatíveis, com diferença máxima de 3,8% com os valores obtidos utilizando o sistema padrão secundário do LCI.
Título en inglés
Establishment a primary standard system for low energy X-rays using a free air ionization chamber
Palabras clave en inglés
free air ionization chamber
mammography
primary standard
X-rays
Resumen en inglés
In this work a primary standard system was established for low energy X-rays (10 kV to 50 kV), using a free air ionization chamber with concentric cylinders, Victoreen (Model 481-5), at the Calibration Laboratory of Instruments (LCI) of the Instituto de Pesquisas Energéticas e Nucleares (IPEN/CNEN-SP). For this, a new ionization chamber alignment protocol was developed for the radiation system and a modification on the micrometer housing used for the movement of the internal cylinders was made. The results obtained for the stability and characterization tests showed to be within the limits established by the standards IEC 61674 and IEC 60731. The correction factors for photon attenuation in the air, transmission and scattering in the diaphragm, scattering and fluorescence and ion recombination were also determined. These values were compared with those obtained by the German primary standard laboratory, Physikalisch-Technische Bundesanstalt (PTB), showing good agreement. Finally, the absolute values of the quantity air kerma rate for the standard qualities direct beams MWV28 and WMV35 and the attenuated beams WMH28 and WMH35 were determined; the results are in agreement, with a maximum difference of 3,8% with the values obtained using the secondary standard system of LCI.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Fecha de Publicación
2016-05-06
 