Disertación de Maestría
DOI
https://doi.org/10.11606/D.85.2019.tde-20032019-145549
Documento
Autor
Nombre completo
Renato Rache Gaspar
Dirección Electrónica
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
São Paulo, 2019
Director
Tribunal
Calvo, Wilson Aparecido Parejo (Presidente)
Karam Junior, Dib
Soares, José Roberto
Título en portugués
Desenvolvimento do sistema de potência elétrica em uma unidade móvel de irradiação por feixe de elétrons para tratamento de águas residuárias e efluentes industriais
Palabras clave en portugués
acelerador industrial de elétrons
distorção harmônica
qualidade de energia elétrica
unidade móvel de irradiação
Resumen en portugués
O tratamento de águas residuárias e efluentes industriais por irradiação com feixe de elétrons é uma técnica promissora, porém pouco difundida em território Brasileiro. O projeto e a construção de uma unidade móvel contendo um acelerador industrial de elétrons de 700 keV e 20 kW, pelo Instituto de Pesquisas Energéticas e Nucleares (IPEN), é inovador para demonstrar os efeitos e resultados positivos dessa tecnologia. O propósito é deslocar a unidade móvel às diversas empresas com interesse em tratamento dos resíduos líquidos, conectar-se ao sistema elétrico da mesma e iniciar o processo de tratamento por ionização, por meio da irradiação com feixe de elétrons. A conexão da unidade móvel ao sistema elétrico local pode representar um desafio, pela grande diversidade de tensões e distâncias envolvidas, e também pelas grandes injeções de conteúdo harmônico gerado pelo acelerador de elétron que podem afetar as cargas do sistema industrial, comumente sensíveis. Neste trabalho realizou-se uma análise do sistema de potência da unidade móvel, quanto à capacidade de interrupção, seletividade da proteção e níveis de curto-circuito adequados de forma a assegurar uma maior confiabilidade na operação. Ao final, projetou-se e construiu-se o painel elétrico de controle da unidade móvel de irradiação. Além disso, na obtenção de parâmetros operacionais à unidade móvel, realizaram-se simulações e medições no acelerador industrial de elétrons de 1,5 MeV e 37,5 kW, instalado no Laboratório de Fontes Intensas de Radiação, do Centro de Tecnologia das Radiações, as quais demonstraram a necessidade da inserção de um filtro para redução dos índices de distorção nos harmônicos dessa instalação radiativa fixa no IPEN.
Título en inglés
Developing an electrical power system of a mobile electron beam accelerator to treatment of industrial wastewaters and effluents
Palabras clave en inglés
electric power quality
harmonic distortion
industrial electron accelerator
mobile irradiation unit
Resumen en inglés
The treatment of wastewater and industrial effluents by electron beam irradiation is a promising technique, however, not very widespread in Brazilian territory. The design and a construction of a mobile unit containing an electron beam accelerator of 700 KeV and 20kW, by the Nuclear and Energy Research Institute (IPEN) is innovative to demonstrate the effects and positive results of this technology. The aim is to move the mobile unit to several companies with interest in liquid waste treatment, and connect to the industry electrical system and start the ionization treatment process through electron beam. The mobile unit's connection to the local electrical system can be a challenge in behalf of the great diversity of voltages and distances involved, as well as the large injections of harmonic content generated by the electron beam accelerator that can affect sensitive loads in the industrial system. In this work, an analysis was made of the power system of the mobile unit, regarding interruption capacity, selectivity protection and adequate short circuit levels in order to assure a greater reliability in the operation. At the end, the control panel of the mobile unit, simulations and measurements were carried out at the 1.5 MeV and 37.5 kW electron beam accelerator, installed at the Intensive Radiation Technology Center, which demonstrated the necessity of applying of a filter to reduce the measured harmonic distortion.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.