Mémoire de Maîtrise
DOI
https://doi.org/10.11606/D.85.2015.tde-18062015-143835
Document
Auteur
Nom complet
Robson Petroni
Adresse Mail
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
São Paulo, 2015
Directeur
Jury
Moreira, Edson Gonçalves (Président)
Prada, Silvio Miranda
Saiki, Mitiko
Titre en portugais
Validação dos métodos de análise por ativação do Laboratório de Análise por Ativação Neutrônica do IPEN - CNEN/SP visando à produção de materiais de referência certificados
Mots-clés en portugais
ABNT ISO 17025
INAA
MRC
planejamento fatorial
validação
Resumé en portugais
Este trabalho de mestrado teve como objetivo realizar a validação formal para quatro métodos de medição do Laboratório de Ativação Neutrônica (LAN) do IPEN - CNEN/SP por Análise por Ativação com Nêutrons Instrumental (INAA). Os mensurandos foram a concentração total de As em tecido de mexilhão (método-BIO-1), a concentração total de Co, Cr, Fe, Rb, Sc, Se e Zn em tecido de mexilhão (método-BIO-2), a concentração total de As e Sb em sedimento marinho (método-GEO-1) e a concentração total Co, Cr, Fe, Sc e Zn em sedimento marinho (método-GEO-2). Em um primeiro momento, foi realizado um estudo univariado para investigar a influência causada ao resultado final em diferentes configurações no preparo dos padrões sintéticos e no tempo de medição da atividade do mensurando no padrão sintético. Outras variáveis, como o tempo de medição da atividade do mensurando na amostra, distância entre amostra e detector e tempo de decaimento para medição da amostra foram estudadas em um processo multivariado, por meio da realização de um Planejamento Fatorial 23 completo (DOE). Os parâmetros de desempenho estudados para a validação dos métodos de medição em INAA foram: seletividade, exatidão (precisão e veracidade), linearidade, faixa de trabalho, seletividade, limite de detecção, limite de quantificação, robustez e incerteza de medição. Os métodos foram validados de acordo com as recomendações do Guia de validação do INMETRO DOQ-CGCRE-008. A estimativa das fontes de incertezas foi realizada de acordo com as recomendações do Guia para a expressão da incerteza de medição (ISO GUM) com o uso do método simulado.
Titre en anglais
Validation of the Neutron Activation Analysis methods of the Neutron Activation Laboratory at IPEN-CNEN/SP aiming the production of certified reference materials
Mots-clés en anglais
CRM
experimental design
INAA
ISO/IEC 17025
method validation
Resumé en anglais
The objective of this study was the validation of four measurement methods by Instrumental Neutron Activation Analysis (INAA) at the Neutron Activation Laboratory (LAN) of IPEN - CNEN/SP. The measurands were: mass fraction of As in biological matrix sample (método-BIO-1), mass fraction of Co, Cr, Fe, Rb, Sc, Se and Zn in biological matrix sample (método-BIO-2), mass fraction of As and Sb in geological matrix sample (método-GEO-1) and mass fraction of Co, Cr, Fe, Sc and Zn in geological matrix sample (método-GEO-2). First, a univariate method optimization was performed to investigate the influence of the the preparation of synthetic standard (monoelemental standard and/or multielemental standard) and standard measurement times. In a second step, a multivariate method optimization was carried to verify the influence of sample measurement time, sample decay time and sample distance to detector by means of a 23 full factorial design (DOE). Investigated method performance characteristics were: selectivity, accuracy (trueness and precision), linearity, work range, selectivity, limit of detection, limit of quantification, robustness and measurement uncertainty. The methods were validated according to recommendations of INMETRO DOQ-CGCRE-008 Validation Guide. The estimate of uncertainty sources was carried out according to recommendations of Guide to the expression of uncertainty in measurement (ISO GUM) using the simulated method.
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
Date de Publication
2015-07-17
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.