• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Doctoral Thesis
DOI
https://doi.org/10.11606/T.85.2019.tde-17102019-103539
Document
Author
Full name
Diego Vergaças de Sousa Carvalho
E-mail
Institute/School/College
Knowledge Area
Date of Defense
Published
São Paulo, 2019
Supervisor
Committee
Mesquita, Carlos Henrique de (President)
André, Claudio Fernando
Matsumoto, Marcio Yuji
Velo, Alexandre França
Title in Portuguese
Desenvolvimento e análise de um sistema multicanal e multifontes para tomografia de processos industriais em tempo real
Keywords in Portuguese
Industrial Process Tomography
instant non-scanning
detector de NaI(Tl)
multicanal
multifontes
tomografia industrial
Abstract in Portuguese
O uso da tomografia computadorizada despertou o interesse das indústrias pela possibilidade em utilizar as informações tomográficas de um produto, de processo ou de equipamento, para auxiliar no controle da qualidade de produtos e também para aperfeiçoar o processo produtivo. Porém, quando se trata de tomografia industrial, ao contrário da já amplamente utilizada tomografia médica, nem sempre as condições para a realização da aquisição tomográfica são favoráveis, pois os objetos industriais podem ter diferentes dimensões, composição química e densidades. O objetivo deste trabalho foi desenvolver um novo desenho para o sistema de tomografia computadorizada industrial, Industrial Process Tomography (tomógrafo), para análises de sistemas multifásicos. Nesta proposta, foram utilizados 70 conjuntos de cristais detectores de NaI(Tl) fotomultiplicadoras, ligados a 5 módulos com 12 detectores. A configuração desenvolvida permitiu a obtenção de um halo de 360° ao redor do objeto a ser tomografado, além da análise em tempo real do processo industrial. O sistema de porta-fontes, desenvolvido para este projeto, permite acomodar dois isótopos radioativos, que com a eletrônica do tipo multicanal, também desenvolvida durante este projeto, possibilitou realizar a seleção de várias faixas espectrais, ao mesmo tempo, em cada detector. O porta-fontes ainda conta com sistema de abertura e de fechamento à distância, para segurança do operador. O tomógrafo, desenvolvido para este trabalho, atendeu às expectativas. Seu desenho possibilita o transporte para as plantas de trabalho, pois este tomógrafo é modular, e apresentou também os picos característicos referentes aos espectros radioativos utilizados, além de apresentar um tempo de aquisição de espectros rápido, o que possibilita a realização de tomografias em tempo real.
Title in English
Development and analysis of a multichannel and multi-source system for real-time industrial process tomography
Keywords in English
Industrial Process Tomography
industrial tomography
instant non-scanning
multi-sources
multichannel
NaI(Tl) detector
Abstract in English
Computerized tomography has promoted the interest of industries for the possibility of using the tomographic data of a product, process, or equipment for quality control of a product, and improve the production process. However, unlike the already widely used medical tomography if compared to industrial tomography, the conditions to perform tomographic acquisition are not always favorable, once industrial objects may have different dimensions, chemical composition, and densities. The aim of this work was to develop a new design for the Industrial Process Tomography (IPT), for multiphase analysis. In this work, 70 sets of photomultiplier with NaI(Tl) detector crystals, connected to 5 modules with 14 detectors, were used. The developed configuration allowed to obtain a 360 ° halo around the object to be tomographed, and, also, real-time analysis of industrial processes. The source holder system developed can accommodate two radioactive isotopes, which with the multichannel electronics as well developed during this project, made it possible to select several spectral bands at the same time, in each detector. The source holder also has a remote opening and closing system for operator safety. The tomography developed for this work reached the expectations; its design turns it possible to transport it to the industrial plants because this tomography is modular, it also presented the characteristic peaks related to the radioactive sources spectra used, besides presenting a fast spectra acquisition time, which enables real-time CT scans.
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.
Publishing Date
2019-11-07
 
WARNING: Learn what derived works are clicking here.
All rights of the thesis/dissertation are from the authors
CeTI-SC/STI
Digital Library of Theses and Dissertations of USP. Copyright © 2001-2024. All rights reserved.