• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Master's Dissertation
DOI
https://doi.org/10.11606/D.85.2009.tde-16112009-135954
Document
Author
Full name
Cléber Feijó Silva
Institute/School/College
Knowledge Area
Date of Defense
Published
São Paulo, 2009
Supervisor
Committee
Rodrigues, Letícia Lucente Campos (President)
Nersissian, Denise Yanikian
Pereira, Maria da Conceição Costa
Title in Portuguese
Avaliação dosimétrica da resposta espectrofotométrica da solução  gel de Alanina para radiação gama, de fótons, de elétrons e de nêutrons térmicos
Keywords in Portuguese
Alanina
Espectrofotometria
Gel
Abstract in Portuguese
O dosímetro alanina gel é um novo material na forma de gel desenvolvido pelo IPEN, que apresenta uma melhora significativa em relação ao sistema a base de Alanina desenvolvido por Costa. A DL-Alanina (C3H7NO2) é um aminoácido tecido equivalente que favorece a produção de íons Férricos na solução. Este trabalho visa analisar as principais características dosimétricas deste novo material na forma de gel para futura aplicação na medida da distribuição da dose. Foi avaliado o desempenho da solução gel de Alanina para radiação gama, de fótons, de elétrons e de nêutrons térmicos utilizando a técnica de espectrofotometria. De acordo com os resultados obtidos para os diferentes tipos de radiação estudados, as reprodutibilidades intra e inter-lotes são melhores que 4% e 5%, respectivamente. A resposta em função da dose apresenta um comportamento linear para o intervalo de dose estudado. A dependência da resposta em função da taxa de dose e energia da radiação incidente é melhor que 2% e 3%, respectivamente. A dose mínima detectável é 0,1 Gy. Os resultados obtidos indicam que o dosímetro Alanina gel apresenta um bom desempenho, e pode ser usado como dosímetro alternativo na área de radioterapia, utilizando a técnica de ressonância magnética para avaliar a distribuição tridimensional de dose.
Title in English
DOSIMETRIC EVALUATION OF SPECTROPHOTOMETRIC RESPONSE OF ALANINE GEL SOLUTION FOR GAMMA, PHOTONS, ELECTRONS AND THERMAL NEUTRONS RADIATIONS
Keywords in English
Alanina
Espectrofotometria
Gel
Abstract in English
Alanine Gel Dosimeter is a new gel material developed at IPEN that presents significant improvement on Alanine system developed by Costa. The DL-Alanine (C3H7NO2) is an amino acid tissue equivalent that improves the production of ferric ions in the solution. This work aims to analyse the main dosimetric characteristics this new gel material for future application to measure dose distribution. The performance of Alanine gel solution was evaluated to gamma, photons, electrons and thermal neutrons radiations using the spectrophometry technique. According to the obtained results for the different studied radiation types, the reproducibility intra-batches and inter-batches is better than 4% and 5%, respectively. The dose response presents a linear behavior in the studied dose range. The response dependence as a function of dose rate and incident energy is better 2% and 3%, respectively. The lower detectable dose is 0.1 Gy. The obtained results indicate that the Alanine gel dosimeter presents good performance and can be useful as an alternative dosimeter in the radiotherapy area, using MRI technique for tridimensional dose distribution evaluation.
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.
CleberFeijoSilva.pdf (1.38 Mbytes)
Publishing Date
2009-12-01
 
WARNING: Learn what derived works are clicking here.
All rights of the thesis/dissertation are from the authors
CeTI-SC/STI
Digital Library of Theses and Dissertations of USP. Copyright © 2001-2024. All rights reserved.