Avaliação das ferramentas de controle de qualidade para pacientes submetidos ao IMRT
Palabras clave en portugués
controle de qualidade
dosimetria
radioterapia de intensidade modulada
Resumen en portugués
Atualmente a radioterapia de intensidade modulada (IMRT) está sendo implementada em um número crescente de centros no Brasil. Como conseqüência disto, muitas instituições estão enfrentando o problema de executar um programa de controle de qualidade antes e durante a execução do IMRT na prática da rotina clínica. O objetivo deste trabalho é avaliar e propor uma metodologia para o controle de qualidade de tratamentos com IMRT. Uma câmara de ionização e um detector bidimensional foram utilizados para avaliar a dose absoluta total de todos os campos em um determinado ponto. A distribuição de dose relativa total de todos os campos foi medida com filmes radiocrômicos e um detector bidimensional em uma profundidade no objeto simulador. Uma comparação entre as distribuições de dose medidas e calculadas foi realizada usando o método do índice gama, avaliando o percentual de pontos que satisfazem os critérios de diferença dose de ±3% e distância de concordância de ±3 mm. Como resultado da dosimetria absoluta de 113 feixes de IMRT medidos com uma câmara de ionização e 81 feixes usando o detector bidimensional, foi proposto um nível de ação de cerca de ± 5% em relação ao sistema de planejamento e de tratamento para a verificação da dose em um único ponto na região de baixo gradiente de dose. A análise das medições com o detector bidimensional mostrou que o valor da função gama foi <1 para 97,7% dos dados e, para o filme, o valor da função gama foi <1 para 96,6% dos dados. Neste trabalho pode-se concluir que para uma entrega exata de dose em IMRT sliding-window com um colimador micro multilâminas, os parâmetros de dose total absoluta e distribuição de dose total relativa devem ser verificados por dosimetria absoluta e relativa respectivamente.
Título en inglés
Evaluation tools of quality control for patients submitted to IMRT
Palabras clave en inglés
dosimetry
IMRT
quality control
Resumen en inglés
Intensity modulated radiation therapy (IMRT) is currently been implemented in a rapidly growing number of centers in Brazil. As consequence many institutions are now facing the problem of performing a comprehensive quality control program before and during the implementation of IMRT in the clinical routine practice. The aim of this work is to evaluate and propose a methodology for quality assurance in IMRT treatments. An ionization chamber and a two-dimensional array detector were performed to assess the absolute value of the total dose of all fields in one specific point. The relative total dose distribution of all fields was measured with a radiochromic film and a two-dimensional array at one depth in a phantom. A comparison between measured and calculated dose distributions was performed using the gamma-index method, assessing the percentage of points that meet the criteria of ±3% dose difference and ±3 mm distance to agreement. As a result of 113 tested IMRT beams using ionization chamber and 81 using two-dimensional array, the proposal was to take an action level of about ± 5% compared to the treatment planning systems and measurements, for the verification of the dose in a single point at the low gradient dose region. Analysis of the two-dimensional array measurements showed that the gamma value was <1 for 97.7% of the data and for the film the gamma value was <1 for 96.6% of the data. This can be concluded that for an accurate delivery of dose in sliding-window IMRT with micro multileaf collimator, the absolute value of the total dose and the relative total dose distribution should be checked by absolute and relative dosimetry respectively.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Fecha de Publicación
2011-06-22
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.