• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Master's Dissertation
DOI
https://doi.org/10.11606/D.85.2007.tde-16062008-154035
Document
Author
Full name
Flavio Betti
E-mail
Institute/School/College
Knowledge Area
Date of Defense
Published
São Paulo, 2007
Supervisor
Committee
Potiens, Maria da Penha Albuquerque (President)
Rodrigues Junior, Orlando
Terini, Ricardo Andrade
Title in Portuguese
Desenvolvimento e implantação de um programa de controle e aquisição de dados na calibração de instrumentos em radiodiagnóstico
Keywords in Portuguese
automação
calibração
dosimetria
LabVIEW
radiodiagnóstico.
Abstract in Portuguese
Neste trabalho foram desenvolvidas as técnicas para projetar e implantar um sistema automatizado de controle e aquisição de dados para o arranjo de calibração em radiação X níveis diagnóstico e radioproteção do Laboratório de Calibração de Instrumentos (LCI) do IPEN. Os programas desenvolvidos fornecem diretamente os valores de kerma corrigidos para as condições ambientais. A automatização do obturador viabilizou a temporização precisa de exposições de curta duração. A utilização da câmara monitora como padrão de calibração beneficiou-se de um programa para a determinação de seus fatores de calibração a partir de uma câmara de referência para as diferentes qualidades de feixe. Foram utilizados como instrumentos de referência, dois eletrômetros, um para a câmara monitora, e outro para a câmara padrão; um termômetro de dois canais, e um barômetro absoluto, todos comunicando-se com o microcomputador através de interface padrão RS-232. São descritos os métodos computacionais utilizados nos programas de controle do kerma pela câmara monitora, bem como no de obtenção de seus fatores de calibração. A linguagem de programação adotada (LabVIEW MR) permitiu a obtenção de resultados rápidos e adequados. Os resultados obtidos demonstraram que o novo sistema proposto está apto a substituir as técnicas anteriormente adotadas no LCI, com vantagens no que diz respeito à rapidez e precisão na execução das calibrações, notadamente sob situações adversas, como as observadas em exposições muito curtas, ou então longas o suficiente para que sejam substancialmente afetadas pela flutuação de parâmetros tais como a taxa de kerma do gerador de raios X, ou então pelas condições ambientais de temperatura e pressão.
Title in English
DEVELOPMENT AND IMPLANTATION OF A CONTROL AND DATA ACQUISITION PROGRAM FOR THE CALIBRATION OF INSTRUMENTS FOR DIAGNOSTIC RADIOLOGY
Keywords in English
automação
calibração
dosimetria
LabVIEW
radiodiagnóstico.
Abstract in English
Design techniques of an automatic control system implementing corrected kerma determination and shutter command in the calibration laboratory at IPEN are shown, as well as the periodic calibration program developed for a monitor chamber for several X-ray beam qualities used for diagnostic radiology and radiation protection instruments. Two reference electrometers, a multichannel secondary standard thermometer, and an absolute pressure barometer were connected to the RS-232 interface from a PC computer equipped with a National Instruments multifunction analog and digital I/O card. LabVIEW MR was chosen as programming tool, which allowed for the development of a suite of programs for both controlling the shutter timing cycles and the calibration of the monitor chamber against a reference standard. A detailed description of the methods used for troubleshooting, fine tuning of parameters and evaluation of program results is followed by an analysis showing that considerable advantages regarding reduction of time and precision improvements during the calibrations could be achieved by the use of the developed programs, particularly under adverse conditions like those found during short expositions, or instead during long irradiation intervals where fluctuation of parameters like kerma rate or room conditions (temperature or pressure) can be found.
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.
Tese_Flavio_Betti.pdf (1.35 Mbytes)
Publishing Date
2008-06-30
 
WARNING: Learn what derived works are clicking here.
All rights of the thesis/dissertation are from the authors
CeTI-SC/STI
Digital Library of Theses and Dissertations of USP. Copyright © 2001-2024. All rights reserved.