Título en portugués
Desenvolvimento e caracterização de um gel de alanina para aplicação na medida da distribuição da dose de radiação usando a técnica de espectrofotometria
Palabras clave en portugués
alanina
dosímetro gel
espectrofotometria
Resumen en portugués
Este trabalho tem por objetivo a composição e caracterização de um dosímetro à base de DL-Alanina e Ferro-ll em forma de gel para aplicações em dosimetría para campos de doses da radiação gama do Co-60 experimentadas em procedimentos de radioterapia. O aminoácido DL-Alanina é dissolvido em solução ácida contendo o Fe-ll e adicionado o gel. Procedeu-se a uma série de ensaios variando reagente a reagente e realizando procedimentos para avaliar o comportamento em função do tempo do gel dosimétrico obtido. Os espectros de absorção antes e após a irradiação apresentam máximos em 457 nm e 588 nm, respectivamente. Esses dois picos correspondem aos comprimentos de onda de absorção das espécies Fe-ll e Fe-lll, respectivamente; estando ambas as espécies em equilíbrio. Com a irradiação, ocorre a formação de radicais que oxidam o Fe-ll em Fe-lll, alterando com isso o balanço entre as duas espécies - daí o aumento da concentração de Fe-lll - fazendo com que mude a tonalidade do gel, sendo, portanto, possível de ser determinada a dose absorvida. Nas análises dos espectros e respectivas curvas dose-resposta observou-se que o gel dosimétrico apresenta linearidade no intervalo de doses entre 0,5 e 40 Gy. A partir dos resultados obtidos de linearidade, estabilidade e menor dose detectável - 0,3 Gy - conclui-se que o presente Gel Dosimétrico à base de DL-Alanina e Fe-ll apresenta excelente potencial para a finalidade que é proposto, qual seja a determinação do campo de doses em radioterapia e futura aplicação como padrão na determinação desses campos, em 3D, utilizando-se a técnica de Imagem por Ressonância Magnética - IRM.
Título en inglés
Developement and characterization of an DL-Alanine gel to be applied in the measurement of the dose distribution with the spectrophotometry technique
Palabras clave en inglés
alamines
cobalt 60
dosimeters
gamma radiation
gels
magnetic resonance
radiation dose distributions
radiotherapy
spectrothotometry
Resumen en inglés
The aim of this work is to develop a DL-Alanine, Fe-ll based gel dosimeter to be applied in the dosimetry of the Co-60 gamma-radiation fields in the dose range of radiation therapy procedures. The aminoacid DL-Alanine is dissolved in an acid solution containing the Fe-ll and added to the gel. A series of essays was performed with different chemicals and different procedures were made to evaluate the behavior of the obtained dosimetric gel as function of the time. The absorption spectra, before and after the irradiation, present maximum in 457 nm and 588 nm, respectively. These two peaks correspond to absorption wavelengths of the chemical species Fe-ll and Fe-lll, respectively, both species being in equilibrium. With the irradiation, the formation of the radicals that oxide the Fe-ll into Fe-lll occurs, altering the chemical balance of both species - hence the increase of the Fe-lll - and causing the gel to change its tonality, in such a way that it is possible to determine the absorved dose. In the analysis of the spectra and respective dose-response curves it was observed that the dosimetric gel shows linearity in dose range of 0.5 to 40 Gy. From the obtained linearity results, stability and lower detectable dose - 0,3 Gy - it is possible to conclude that the present DL-Alanine, Fe-ll based dosimetric gel presents an excellent potential to the application to which it is proposed, namely, the determination of the dose fields in radiation therapy and its future application as a standard in the determination of these fields, in 3D, using the Magnetic Resonance Imaging.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Fecha de Publicación
2012-05-30
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.