Tesis Doctoral
DOI
https://doi.org/10.11606/T.85.2007.tde-16052012-104232
Documento
Autor
Nombre completo
Pedro Pereira Rodrigues
Dirección Electrónica
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
São Paulo, 2007
Director
Tribunal
Rodrigues, Letícia Lucente Campos (Presidente)
Caldas, Linda Viola Ehlin
Costa, Paulo Roberto
Ghilardi Netto, Thomaz
Hamada, Margarida Mizue
Título en portugués
Estudos microdosimétricos usando um sistema de irradiação de nêutrons rápidos filtrados de reator de pesquisa para aplicação de radiobiologia
Palabras clave en portugués
dosimetria de nêutrons
microdosimetria
Resumen en portugués
Neste trabalho, medidas microdosimétricas foram realizadas usando um contador proporcional equivalente à tecido - TEPC. com uma cavidade esférica de diâmetro de 1.27 cm. O TEPC foi preenchido com gás propane puro, C3HS, à pressão de 5,6 kPa (42 Torr), que é equivalente a 1,3 μm em diâmetro de unidade de densidade do tecido. O instrumento de medida microdosimétrica foi irradiado com radiação de nêutrons rápidos do reator de pequisa do Nuclear Science Center da Texas A&M University, em College Station,-Texas. Os feixes de nêutrons rápidos foram emitidos com três diferentes valores de potência. 0,5, 1,0, e 2,0 kVV, durante 1 hora para alto ganho e o mesmo tempo para baixo ganho, totalizando 2 horas para cada potência, com 0,0083 Gy/min de taxa de dose. O neutron foi filtrado usando o sistema de irradiação de néutrons rápidos fortemente nitrados (FNIS). do Nuclear Science Center, para obter uma redução da contaminação da radiação de neutron por radiação gama e assim obter espectros microdosimetricos de neutrons como, distribuição de freqüência de energia lineal e distribuição de dose de energia lineal, com boa precisão, e outras grandezas como, freqüência média de energia lineal, dose média de energia lineal, dose absorvida, dose equivalente e fator de qualidade médio de neutron rápido. Os resultados obtidos foram satisfatórios, com os espectros microdosimetricos de nêutrons mostrando uma contaminação de radiação gama abaixo de 5 %, especialmente para distribuição de dose de energia lineal. Os resultados obtidos neste trabalho foram comparados com outros da literatura científica, que usaram outros procedimentos para a redução da contaminação do neutron por radiação gama. estando em concordância com eles.
Título en inglés
Microdosimetric studies using a filtered fast neutron irradiation system of research reactor to application in radiation biology
Palabras clave en inglés
fast neutrons
filters
microdosimetry
radiations
radiobiology
research reactors
wall-less counters
Resumen en inglés
In this work, microdosimetric measurements were performed using a Wall-less Tissue Equivalent Proportional Counter - TEPC was filled with spherical cavity with an inner diameter of 1.27 cm. The TEPC was tilled with pure propane gas, C3H8 at 5.6 kPa (42 Torr) pressure, which is equi\alent to 1.3μm in diameter of unit density tissue. The microdosimetric measurement device was irradiated with fast neutron radiation from Texas A&M University Nuclear Science Center research reactor, in College Station, Texas. The fast neutron beams were emitted with three different power values, 0.5, 1.0 and 2.0 kW. during Ih for both high gain and low gain, totalizing two hours for each power with 0.0083 Gy/min of dose rate. The neutron was filtered using the heavily filtered fast neutron irradiation s\stem (FNIS). from Nuclear Science Center, to obtain a decrease of neutron radiation contamination by gamma ray and so, to gain the neutron microdosimetric spectra as. frequency distribution of lineal energy, dose distribution of lineal energy with good precision, and another quantities as frequency-mean of lineal energy, dose- mean of lineal energy, absorbed dose, equivalent dose and average quality factor of fast neutron. The obtained results were satisfactory, with the neutron microdosimetric spectra showing a gamma ray contamination under 5 %, especially to dose distribution of lineal energy. The results obtained in this work were in agreement when compared with another results from scientific literature, which used another procedure to reduce the neutron contamination by gamma ray.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Fecha de Publicación
2012-05-30
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.