Master's Dissertation
DOI
https://doi.org/10.11606/D.85.2014.tde-15102014-105653
Document
Author
Full name
Felipe Favaro Capeleti
E-mail
Institute/School/College
Knowledge Area
Date of Defense
Published
São Paulo, 2014
Supervisor
Committee
Rodrigues, Letícia Lucente Campos (President)
Galante, Ana Maria Sisti
Nersissian, Denise Yanikian
Title in Portuguese
Dosimetria em tomografia computadorizada e avaliação do perfil de dose empregando dosímetro Fricke gel e a técnica de imageamento por ressonância magnética
Keywords in Portuguese
Fricke Gel
perfil de dose
ressonância magnética
tomografia
Abstract in Portuguese
Neste trabalho foi desenvolvido um novo método para a determinação das doses absorvidas nos exames de tomografia computadorizada, utilizando a dosimetria com Fricke gel desenvolvido no IPEN. Foram determinadas as doses absorvidas por diferentes metodologias de análise, como a espectrometria de absorção óptica, câmaras de ionização e imageamento por ressonância magnética. Foram realizados testes de limite mínimo de sensibilidade da solução de Fricke gel, repetitividade de sinal da solução de Fricke gel e dos equipamentos de tomografia computadorizada, sensibilidade de detecção, entre outros. Foram utilizados diferentes equipamentos de tomografia computadorizada com múltiplos detectores. A solução Fricke gel apresentou repetitividade melhor que ± 5,5% utilizando a técnica de espectrofotometria de absorção óptica e os equipamentos de tomografia computadorizada apresentaram repetitividade melhor que ± 0,2%. Foi desenvolvido um objeto simulador de crânio preenchido com a solução Fricke gel para a determinação da colimação total do equipamento e a distribuição de dose utilizando a técnica de imageamento tridimensional por ressonância magnética. A solução Fricke gel apresenta um preparo fácil e relativamente rápido, porém é necessária atenção para não haver contaminação e perder a solução. Com os resultados obtidos foi confirmada a aplicação deste tipo de dosimetria para os equipamentos de tomografia computadorizada.
Title in English
Dosimetry for computed tomography and evaluation the dose profile using Fricke Gel dosimetry and magnetic ressonance imaging
Keywords in English
dose profile
Fricke Gel
Magnetic resonance
tomography
Abstract in English
In this work it was determined a new method for the determination of absorbed doses in Computed Tomography (CT) examinations using Fricke gel dosimetry developed at IPEN. Absorbed doses were determined by different methods of analysis, such as optical absorption spectrometry, ionization chambers and magnetic resonance imaging. Lower limit of sensitivity of the Fricke gel solution, the solution repeatability signal Fricke gel and CT equipment, detection sensitivity, among other tests were performed. Different equipment of computed tomography with multiple detectors were used. The Fricke gel solution showed better repeatability than 5.5% using the technique of optical absorption spectrophotometry and computed tomography equipment showed repeatability better than ± 0.2%. It was developed a skull phantom which was filled with Fricke gel solution for determining the total collimation of the equipment and the dose distribution using the technique of three-dimensional magnetic resonance imaging. The Fricke gel solution features an easy and relatively quick preparation, but it is necessary to be careful not to contaminate and lose the solution. With the results it was confirmed the application of this type of dosimetry for computed tomography equipment.
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.
Publishing Date
2014-11-07
 
WARNING: Learn what derived works are clicking here.
All rights of the thesis/dissertation are from the authors
CeTI-SC/STI
Digital Library of Theses and Dissertations of USP. Copyright © 2001-2024. All rights reserved.