• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Doctoral Thesis
DOI
https://doi.org/10.11606/T.85.2012.tde-15042013-140936
Document
Author
Full name
Marina Ferreira Lima
E-mail
Institute/School/College
Knowledge Area
Date of Defense
Published
São Paulo, 2012
Supervisor
Committee
Mesquita, Carlos Henrique de (President)
Carneiro, Janete Cristina Gonçalves Gaburo
Guimaraes, Maria Ines Calil Cury
Santos, Raquel Gouvea dos
Todo, Alberto Saburo
Title in Portuguese
Proposição de modelos cinéticos e alométricos para a dosimetria de radiofármacos marcados com lantanídeos
Keywords in Portuguese
alometria
análise compartimental
cinética
dosimetria
Lutécio-177
Abstract in Portuguese
Este trabalho apresenta dois modelos baseados em análise compartimental: modelo Animal e modelo Humano, usando imagens obtidas com mini gama câmera e dados de pacientes (obtidos da literatura) para a determinação das constantes cinéticas na biodistribuição do 177Lu-DOTATATO para três espécies animais (rato Wistar, hamster armênio e hamster sírio) e para o Humano. Os estudos de biodistribuição consideraram duas fases: a Fase 1, governada pela transferência do sangue para os órgãos e a Fase 2 governada pela excreção renal. As constantes cinéticas calculadas a partir dos dados obtidos com os animais foram usadas para a construção de escalas alométricas para prever a biodistribuição do radiofármaco 177Lu-DOTATATO empregando relações de massa, metabolismo, longevidade e parâmetros fisiológicos. Os resultados de extrapolação foram comparados com resultados calculados diretamente para os pacientes de PRRT (Peptide Receptor Radiotherapy) usando o modelo Humano. As constantes cinéticas calculadas a partir dos dados obtidos com humanos foram usadas para estimativa de dose em pacientes de PRRT considerando 26 órgãos e tecidos considerados pelo método MIRD. Os resultados de dosimetria foram concordantes com aqueles disponíveis na literatura. Para a Fase 1, as relações alométricas para as constantes cinéticas dos principais órgãos envolvidos no metabolismo e excreção do 177Lu-DOTATATO - fígado, rins e bexiga - mostraram boa correlação na projeção por massa, por metabolismo e por parâmetros fisiológicos. Para a Fase 2, apenas as constantes do sangue para os rins e do sangue para o fígado apresentaram boa correlação. Considerando o efeito de bloqueio da excreção renal pelo uso de anestésico, não se justificam tempos de medição maiores que 40 minutos para estudos in vivo, em pequenos animais. Dessa maneira, os resultados obtidos com as medições da Fase 1 da biodistribuição do 177Lu-DOTATATO em animais se apresentam como suficientes para estabelecer relações alométricas para estimativa de dose em pacientes submetidos à PRRT.
Title in English
Kinectic and allometric models for dosimetry using radiopharmaceuticals labeled with lanthanides
Keywords in English
allometry
compartmental analyse
dosimetry
kinetic
Lutetium-177
Abstract in English
This work proposes two models based in compartimental analyses: Animal model and Human model, using images from gamma camera measurements to determinate the kinetic constants of the 177Lu-DOTATATE to three animal species (rat Wistar, Armenian hamster and Syrian hamster) and to the human in biodistridution studies split in two phases: Phase 1 governed by uptake from the blood and Phase 2 governed by the real excretion. The kinetic constants obtained from the animals data were used to build allometric scaling to predict radiopharmaceutical biodistribution in the human employing relations by mass, metabolism, by life span and by physiological parameters. These extrapolation results were compared with the PRRT (Peptide receptor radiotherapy) patients kinetic data calculated using the Human model. The kinetic constants obtained from humans were used in dose assessment to PRRT patients considering MIRD 26 organs and tissues. Dosimetry results were in agreement with available results from literature. For the Phase 1 allometric scaling from kinetic data from the blood to the organs straight responsible for the 177Lu-DOTATATO metabolism and excretion - liver, kidneys and urinary bladder -show good correlation in the scaling by mass, metabolism and physiological and parameters. For the Phase 2, only the kinetic data from blood to the liver and to the kidneys show good correlation. Based in the anaesthetics inhibitory action over the renal excretion, there is not empirical basis to allow measurement times over 40 minutes in in vivo studies with small animals. Consequently, the Phase 1 results seem enough to make allometric scaling to assessment dose in PRRT.
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.
2012LimaProposicao.pdf (10.05 Mbytes)
Publishing Date
2013-04-16
 
WARNING: Learn what derived works are clicking here.
All rights of the thesis/dissertation are from the authors
CeTI-SC/STI
Digital Library of Theses and Dissertations of USP. Copyright © 2001-2024. All rights reserved.