• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Master's Dissertation
DOI
https://doi.org/10.11606/D.85.2016.tde-13052016-130311
Document
Author
Full name
Daphne de Souza Said
E-mail
Institute/School/College
Knowledge Area
Date of Defense
Published
São Paulo, 2016
Supervisor
Committee
Matsuda, Margareth Mie Nakamura (President)
Carvalho, Alexandre Zatkovskis
Marques, Fabio Luiz Navarro
Title in Portuguese
Estudo de metodologias de controle de qualidade do Mo-99 utilizado no preparo de geradores de Mo-99/Tc-99m
Keywords in Portuguese
controle de qualidade
espectrometria gama
extração em fase sólida
gerador de Tc-99m
molibdênio-99
Abstract in Portuguese
O 99mTc é o radionuclídeo mais utilizado em medicina nuclear. No Brasil os geradores de 99Mo/99mTc são produzidos exclusivamente pelo Centro de Radiofarmácia do IPEN-CNEN/SP, com 99Mo importado de diferentes fornecedores. O 99Mo (t1/2 = 66 h), por ser um produto de fissão do 235U, pode conter impurezas radionuclídicas prejudiciais à saúde humana. Dessa forma, para que o gerador seja utilizado de forma segura, é necessário que o 99Mo seja avaliado por ensaios de controle de qualidade e atenda à alguma especificação descrita em farmacopeia. A Farmacopeia Europeia (FE) apresenta monografia, com parâmetros (identificação, pureza radioquímica e pureza radionuclídica), métodos de análise, e limites, para avaliação da qualidade da solução de [99Mo] na forma de molibdato de sódio, que é utilizada como matéria-prima no preparo dos geradores de 99Mo/99mTc. No entanto, observa-se uma dificuldade na implementação e execução dos métodos por parte dos produtores de geradores, com pouca literatura sobre o assunto, provavelmente devido à falta de praticidade dos métodos propostos e à extensa lista de reagentes utilizados. Nesse trabalho foram avaliados vários parâmetros de qualidade do 99Mo descritos na monografia da FE. Foram estudados métodos de separação do 99Mo de suas impurezas radionuclídicas por extração em fase sólida (SPE) e por TLC. Após separação por SPE, foi proposta a quantificação de metais por ICP-OES para avaliar a porcentagem de retenção de Mo e a porcentagem de recuperação de Ru e Te e Sr em diversos tipos de cartuchos, em substituição ao uso de radiotraçadores. Observou-se que a marca de cartucho de SPE para separação do 99Mo recomendada pela FE apresentou baixa recuperação para Ru, quando comparado aos outros cartuchos de troca aniônica disponíveis no mercado. Amostras de 99Mo de diferentes fornecedores mundiais foram analisadas. Observou-se que é possível realizar a quantificação de 103Ru em amostras de 99Mo mesmo com tempos de decaimento acima de 4 semanas. Um método alternativo de separação do 99Mo do 131I por TLC apresentou resultados promissores. Não foi feita a quantificação das impurezas radionuclídicas emissoras beta e alfa. Todas as amostras analisadas apresentaram resultados dentro das especificações da FE para pureza radioquímica (>95%) e pureza radionuclídica.
Title in English
Study of methodologies for quality control of 99Mo used in 99Mo/99mTc generators
Keywords in English
gamma spectrometry
molybdenum-99
quality control
solid phase extraction
Tc-99m generator
Abstract in English
99mTc is the most used radionuclide in nuclear medicine. In Brazil, the 99Mo/99mTc generators are exclusively produced by Radiopharmacy Center at IPENCNEN/ SP, by importing 99Mo from different suppliers. 99Mo (t1/2 = 66 h) is a fission product of 235U and it can have radionuclidic impurities that are prejudicial for human health. For safe use of generators, it is necessary to perform the evaluation of 99Mo by quality control tests in order to assess if 99Mo complies with the specifications. The European Pharmacopoeia (EP) presents a monograph for evaluation of the quality of the [99Mo] solution as sodium molybdate,that is used as raw material for 99Mo/99mTc generators production, including specification parameters (identification, radiochemical purity and radionuclidic purity), analysis methods and limits. However, it has been observed difficulties on the execution and implementation of these methods by the generators producers, with a few literature about this subject, probably due to complexity of the proposed methods. In this work, many quality control parameters of 99Mo described in the EP monograph were evaluated. Separation methods for 99Mo from its radionuclidic impurities by solid phase extraction (SPE) and TLC were studied. After SPE separation, the quantification of metals by ICP-OES to evaluate the percentage of retention of Mo and the percentage of recovery of Ru, Te and Sr using different types of cartridges were proposed, replacing radiotracers use. It was observed that the specific type of SPE cartridge recommended by the EP for separation of 99Mo presented low recoveries for Ru, compared to other available anion exchange SPE cartridges. 99Mo samples from different worldwide suppliers were analyzed. It was observed that quantification of 103Ru in 99Mo samples with decay time higher than 4 weeks is possible. An alternative method for separation of 131I from 99Mo showed promising results by TLC. The quantification of beta and alpha emitters radionuclidic impurities was not performed. All analysed samples presented results that comply with EP specifications for radiochemical purity (>95%) and for radionuclidic purity.
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.
2016SaidEstudo.pdf (2.33 Mbytes)
Publishing Date
2016-05-17
 
WARNING: Learn what derived works are clicking here.
All rights of the thesis/dissertation are from the authors
CeTI-SC/STI
Digital Library of Theses and Dissertations of USP. Copyright © 2001-2024. All rights reserved.