• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Doctoral Thesis
DOI
https://doi.org/10.11606/T.85.2018.tde-13032018-101043
Document
Author
Full name
Iremar Alves da Silva Junior
E-mail
Institute/School/College
Knowledge Area
Date of Defense
Published
São Paulo, 2017
Supervisor
Committee
Potiens, Maria da Penha Albuquerque (President)
Bottaro, Márcio
Caldas, Linda Viola Ehlin
Silva, Teógenes Augusto da
Vivolo, Vitor
Title in Portuguese
Desenvolvimento de uma metodologia de calibração de monitores de contaminação de superfície considerando o mapeamento da uniformidade das fontes extensas de referência
Keywords in Portuguese
calibração
fator de correção
fonte extensa de referência
MCNP
monitor de contaminação de superfície
uniformidade
Abstract in Portuguese
Uma das exigências na calibração de monitores de radiação de contaminação de superfície consiste no uso de fontes extensas de referência com um valor de uniformidade superior a 90%. Entretanto, foi verificado em alguns laboratórios de calibração que suas fontes não atendiam essa exigência, o que obrigaria esses laboratórios a não utilizarem tais fontes em suas calibrações. Foi neste contexto que foi desenvolvido um estudo para propor o uso dessas fontes, desde que sejam utilizados fatores de correção, que são propostos neste trabalho, que foram avaliados e desenvolvidos usando o código de transporte MCNP como ferramenta de análise e avaliação, a partir dos dados de mapeamento da uniformidade. Também foi desenvolvido um software para calcular esses fatores de correção, utilizando o mapeamento da uniformidade das fontes como dados de entrada e um sistema automatizado para calibração de monitores de radiação de contaminação de superfície. O grande ganho com esse trabalho foi poder utilizar fontes extensas de referência, mesmo quando essas estão em desacordo com as exigências de uniformidade da norma ABNT ISO 8769:2016.
Title in English
Development of a calibration methodology of surface contamination monitors considering the uniformity mapping of the large area reference sources
Keywords in English
calibration
correction factor
large-area reference source
MCNP
surface contamination monitor
uniformity
Abstract in English
One of the requirements in the calibration of surface contamination radiation monitors is the use of wide area reference sources with a uniformity value greater than 90%. However, it has been found, in some calibration laboratories, that their sources were not meeting this requirement, which would not allow these laboratories to use such sources in their calibration procedures. It was in this context that a study was developed to propose the use of these sources, provided that correction factors are used, which are proposed in this work, which were evaluated and developed using the MCNP radiation transport code as an evaluation tool, from the uniformity mapping data. A software was also developed to calculate these correction factors using the source uniformity mapping as an input data along with an automated system for calibration of surface contamination radiation monitors. The great gain in this work was to be able to use wide area reference sources, even when they are in disagreement with the uniformity requirements of ISO 8769:2016.
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.
Publishing Date
2018-04-11
 
WARNING: Learn what derived works are clicking here.
All rights of the thesis/dissertation are from the authors
CeTI-SC/STI
Digital Library of Theses and Dissertations of USP. Copyright © 2001-2024. All rights reserved.