• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Mémoire de Maîtrise
DOI
https://doi.org/10.11606/D.85.2008.tde-10102011-141504
Document
Auteur
Nom complet
Marcelo di Marcello Valladão Lugon
Adresse Mail
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
São Paulo, 2008
Directeur
Jury
Matsuda, Margareth Mie Nakamura (Président)
Fiorito, Pablo Alejandro
Silva, Constancia Pagano Goncalves da
Titre en portugais
Determinação de Sn(II) por polarografia: aplicação no controle de qualidade de reagentes liofilizados para radiodiagnóstico
Mots-clés en portugais
controle de qualidade
determinação de Sn
eletroquímica
polarografia
reagente liofilizado
Resumé en portugais
Cloreto estanoso (SnCl2.2H2O) é o composto mais utilizado na redução do íon pertecnetato (TcO4-), obtido pela eluição do gerador, para a marcação de reagentes liofilizados para radiodiagnóstico. Estes reagentes liofilizados contêm um ligante, cloreto estanoso, e diferentes excipientes. Muitos métodos analíticos para a determinação de estanho não conseguem distinguir entre os íons estanoso (Sn(II)) e estânico (Sn(IV)) em soluções. Os dois métodos, descritos na literatura, para determinação seletiva de Sn(II) são análise titrimétrica e polarografia. O método mais confiável descrito para a quantificação do íon estanoso é a polarografia (voltametria) e pode ser utilizado para a determinação em concentrações de mg e g de Sn(II) e Sn(IV) (0,06-1,0 mg), com boa seletividade. Foi realizada análise titrimétrica, para quantificação de Sn(II), na matéria-prima e em 3 lotes consecutivos de 9 reagentes liofilizados produzidos pelo IPEN-CNEN/SP, utilizando-se sulfato cérico 0,1 mol L-1, diluído 10 vezes e iodo 0,05 mol L-1, diluído 10 vezes, como soluções titulantes. Polarografia por pulso diferencial foi utilizada com configuração convencional composta por três eletrodos: eletrodo de trabalho de gota de mercúrio, eletrodo referência de Ag/AgCl (saturado com KCl) e eletrodo auxiliar de platina. O intervalo de potencial analisado foi de -250 a -800 mV e o pico atribuído à redução de Sn(II) foi encontrado em -370 mV em eletrólito suporte de H2SO4 3 mol L-1 e, para Sn(IV), -470 mV, em eletrólito suporte de HCl 3 mol L-1. Para retirada do oxigênio da solução na cela polarográfica utilizou-se nitrogênio 5.0 por 5 minutos, antes e após cada introdução de amostra. Para determinação de Sn(IV) foi feita a oxidação do Sn(II), por adição de peróxido de hidrogênio, em 37 ± 5 ºC, por 5 minutos, seguida de purga com nitrogênio, e análise. A análise polarográfica desenvolvida mostrou-se adequada para a determinação de Sn(II), na presença de Sn(IV), e de estanho total nos kits radiofarmacêuticos estudados.
Titre en anglais
Polarographic determination of Sn(II): application in the quality control of radiopharmaceutical reagents
Mots-clés en anglais
diagnosis
polarography
quality control
radiopharmaceuticals
reagents
tin
Resumé en anglais
Stannous chloride (SnCl2.2H2O) is the major compound used for reduction of generator-derived 99mTc-pertechnetate in cold kits for on site preparation of 99mTc-radiopharmaceuticals. These cold kits usually contain a ligand, stannous chloride, and different additives. Various techniques were described for tin determination, but they cannot distinguish between stannous (Sn(II)) and stannic (Sn(IV)) ions in solutions. The two methods described in literature for selective determination of Sn(II) are polarography and mass analysis (redox-titration). Polarography is a good selective method in the mg range as well as in the g range for Sn(II) and Sn(IV) (0.06-1,0mg). Titrimetric analysis was performed for quantification of Sn(II) in Sn(II) reagents and in 3 consecutive lots of 9 radiopharmaceutical cold kits produced by IPEN-CNEN/SP, using Ce(SO4)2.4H2O 0.1 mol L-1, diluted 10 times and, I2 0.05 mol L-1, diluted 10, as a titrant solution. Differential pulse polarography was chosen with a conventional three-electrode configuration consisting of a static mercury drop electrode, an AgCl/Ag (saturated KCl) reference electrode and a platinum wire auxiliary electrode. The potential was swept from 250 to 800 mV and the current (A) was measured at 370 mV and 470 mV potentials for Sn(II) in H2SO4 3 mol L-1 and Sn(IV) in HCl 3 mol L-1, respectively. The supporting electrolytes were deaerated during 5 min with 5.0 nitrogen gas before and after each sample addition. For total tin determination the oxidation of tin (II) was carried out in the same vial, by adding H2O2 at 37 ± 5 ºC, for 5 min to quantify tin (IV). The developed polarographic method showed to be adequate to quantify tin (II), in the presence of tin (IV), in analyzed radiopharmaceutical cold kits.
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
Date de Publication
2011-10-17
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.