Disertación de Maestría
DOI
https://doi.org/10.11606/D.85.2017.tde-10082017-113643
Documento
Autor
Nombre completo
Jamille da Silveira Almeida
Dirección Electrónica
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
São Paulo, 2017
Director
Tribunal
Koskinas, Marina Fallone (Presidente)
Medeiros, José Agostinho Gonçalves de
Vanin, Vito Roberto
Título en portugués
Estudo das impurezas radioativas gama emissoras presentes nos radiofármacos produzidos no IPEN-CNEN/SP
Palabras clave en portugués
espectrometria gama
impurezas radionuclídicas
radiofármacos
Resumen en portugués
Este trabalho tem como objetivo investigar a concentração de impurezas radioativas gama emissoras presentes nas soluções dos radiofármacos produzidos no Instituto de Pesquisas Energéticas e Nucleares - IPEN em São Paulo. Para que este radiofármaco possa ser utilizado adequadamente, sua qualidade deve ser avaliada de acordo com os procedimentos estabelecidos de acordo com os "Requisitos Gerais para a Competência de Laboratórios de Teste e Calibração", ISO / IEC 17025: 2005 e pelas "Boas Práticas de Fabricação" (BPF), controladas pela ANVISA (Agência Nacional de Vigilância Sanitária), no Brasil. Para determinar a atividade, dos radiofármacos das impurezas gama emissoras, foi utilizado um espectrômetro gama de alta resolução em duas distâncias fonte-detector; uma de 18 cm e outra de 1,7 cm. Para a distância de 18 cm, o espectrômetro HPGe foi calibrado com energias gama entre 81 kev e 1408 kev, medindo ampolas seladas de 60Co, 133Ba, 137Cs e 152Eu, padronizadas no Laboratório de Metrologia Nuclear (LMN) do IPEN. Para impurezas com baixas atividades, utilizou a distância fontedetector de 1,7 cm. A esta distância, o efeito soma em cascata é muito elevado, tornando difícil a medição das ampolas de calibração padrão, com isso, a curva de eficiência do espectrômetro foi obtida por um código de simulação de Monte Carlo, desenvolvido no IPEN. Neste código, todos os detalhes do sistema de detecção são modelados e as curvas de resposta para raios X e raios gama são calculadas pelo código de transporte de radiação MCNPX. Os espectros gama foram analisados pelo programa Alpino, que aplica o método de integração numérica da área sob os fotopicos de absorção total. Para as impurezas gama emissoras não detectadas visualmente, os limites de detecção foram calculados a partir da taxa de contagem de fundo, sob a área do pico de interesse. As soluções radioativas analisadas foram 67Ga,99Mo, 99mTc, 111In, 131I, 153Sm, 177Lu e 201Tl. Os resultados da relação entre a atividade do radionuclídeo em análise e as impurezas identificadas apresentaram acordo com os certificados de análise dos fabricantes, assim como, com as especificações da ANVISA.
Título en inglés
Study of the radioactive impurities gamma emitters present in the radiopharmaceutical solutions produced at IPEN-CNEN/SP
Palabras clave en inglés
gamma spectrometry
radioactive impurities
radiopharmaceutical
Resumen en inglés
This work aims to investigate the concentration of radioactive impurities gamma emitters in the radiopharmaceutical solutions produced at Nuclear and Energy Research Institute -IPEN in São Paulo, So that this radiopharmaceutical may be used properly, its quality should be evaluated in accordance with the procedures established by quality control agencies, such as "General Requirements for the Competence of Testing and Calibration Laboratories", ISO/IEC 17025:2005 and the "Good Laboratory Practice" (GLP), controlled by ANVISA (National Agency Health Surveillance), in Brazil, requiring a confirmation of the values of impurities related at the certificates supplied by the manufacturers. To determine the activity, a high resolution gamma spectrometer were used in two source-detector distances. One was 18 cm and the other 1.7 cm. For the 18 cm distance, the high pure germanium spectrometer was calibrated in the energy range between 81 keV and 1408 keV by measuring sealed ampoules of 60Co, 133Ba, 137Cs and 152Eu, standardized at the Nuclear Metrology Laboratory (NML) of IPEN. For lower activity of the impurities, the distance source-detector of 1.7 cm was assumed. However, as at this distance, the sum coincidence effect is very high, making the measurement of the standard calibration ampoules difficult, the spectrometer efficiency curve was obtained by a Monte Carlo simulation code, developed at IPEN. In this code, all details of the detection system are modeled and the response curves for x-rays and gamma rays are calculated by the MCNPX radiation transport code. The gamma spectra were analyzed by Alpino code, which applies the method of numeric peak integration of the area under the photopeaks. For gamma emitter impurities, not visually detected, the decision threshold and the detection limits were calculated from the background count rate, under the peak area. The radiopharmaceutical solutions analyzed were 67Ga,99Mo, 99mTc, 111In, 131I, 153Sm, 177Lu and 201Tl. The results of impurities ratio for analyzed solutions are in accordance with the manufacturers´ certificate and with the ANVISA.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Fecha de Publicación
2017-09-08
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores