Doctoral Thesis
DOI
https://doi.org/10.11606/T.85.2012.tde-09122013-140708
Document
Author
Full name
Maíra Goes Nunes
E-mail
Institute/School/College
Knowledge Area
Date of Defense
Published
São Paulo, 2012
Supervisor
Committee
Rodrigues, Letícia Lucente Campos (President)
Hamada, Margarida Mizue
Ludwig, Zélia Maria da Costa
Silva, Teresinha de Moraes da
Teixeira, Maria Inês
Title in Portuguese
Desenvolvimento do dosímetro termoluminescente de CaSO4:Ce, Eu para a monitoração individual e a dosimetria clínica de fótons e elétrons
Keywords in Portuguese
dosimetria
monitoração individual externa
sulfato de cálcio
termoluminescência
terras raras
Abstract in Portuguese
Detectores de sulfato de cálcio ativado com cério IV e európio III utilizando o politetrafluoretileno (PTFE, Teflon®) free-flow como aglutinante (CaSO4:Ce,Eu + Teflon®) foram produzidos pelo método da estampagem, desenvolvido em colaboração com a empresa Tecnoflon, a partir de cristais crescidos de acordo com uma nova variação da rota da evaporação lenta, também apresentada nesse trabalho, com as concentrações de 0,16 mol% de Eu3+ e de 0,15 mol% de Ce4+ na solução ácida precursora. O modelo de dosímetro pessoal desenvolvido consiste em cinco detectores aderidos a um cartão de 30 x 48 mm de cloreto de polivinila (PVC) 95% opaco à luz na faixa do espectro eletromagnético que vai do infravermelho ao ultravioleta, idêntico aos cartões de identificação utilizados no IPEN, por uma tira de 10 x 35 mm de filme adesivo do mesmo material e foi submetido aos testes de aceitação descritos no regulamento técnico IRD-RT Nº 002.01/95, Desempenho de Sistemas de Monitoração Individual Critérios e Condições, sendo aprovado em todos os testes. Para a dosimetria clínica, os próprios detectores foram considerados dosímetros termoluminescentes e submetidos aos testes de aceitação descritos no código de práticas da Agência Internacional de Energia Atômica Technical Report Series Nº 398, Absorbed Dose Determination in External Beam Radiotherapy: An International Code of Practice for Dosimetry based on Standards of Absorbed Dose to Water, [TRS-398, IAEA, 2000] adotado como protocolo de dosimetria pela maioria dos hospitais, sendo igualmente aprovados nesses testes. Os dosímetros desenvolvidos podem ser utilizados para a monitoração individual externa e para dosimetria clínica, apresentando a diferenciação do tipo e da energia da radiação com que foram irradiados e a redução de custos como as principais vantagens em relação aos dosímetros termoluminescentes atualmente utilizados nessas aplicações.
Title in English
Development of CaSO4:Ce,Eu thermoluminescent dosimeters for individual monitoring for external exposures and clinical dosimetry
Keywords in English
calcium sulfate
dosimetry
individual monitoring of external exposure
rare earths
thermoluminescence
Abstract in English
Calcium sulphate activated with cerium IV and europium III using the free-flow polytetrafluoroethylene (PTFE, Teflon®) as bonder were produced by the stamping method, developed by the collaboration of Tecnoflon industries, from crystals growth according to a new variation of the slow evaporation method, also described in this study, with Eu3+ and Ce4+ concentrations of respectively 0.15 mol% and 0.16 mol% in the precursory acid solution. The developed personal dosimeter consist of five detectors adhered to a 30 x 48 mm polyvinyl chloride (PVC) card 95% mat to light in the infrared to ultraviolet wavelengths, identical to the access cards used by IPEN staff, by a 10 x 35 mm adhesive strip of the same material and it passed the acceptance tests required by Brazilian national regulatory committee for appliance in individual monitoring of external exposure services. The own detector is considered a dosimeter as far as clinical dosimetry is concerned and it passed the acceptance tests suggested by the International Atomic Energy Agency in the Technical Report Series Nº 398, Absorbed Dose Determination in External Beam Radiotherapy: An International Code of Practice for Dosimetry based on Standards of Absorbed Dose to Water, [TRS-398, IAEA, 2000] adopted as the dosimetry protocol by most hospitals. Hence, the developed dosimeters can be applied in the individual monitoring for external exposure and in the clinical dosimetry, having the radiation type and energy differentiation and the cost reduction as the key advantages over the currently used thermoluminescent dosimeters in such applications.
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.
Publishing Date
2014-01-14
 
WARNING: Learn what derived works are clicking here.
All rights of the thesis/dissertation are from the authors
CeTI-SC/STI
Digital Library of Theses and Dissertations of USP. Copyright © 2001-2024. All rights reserved.