• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Doctoral Thesis
DOI
https://doi.org/10.11606/T.85.2009.tde-09092009-193453
Document
Author
Full name
Pablo Antonio Vasquez Salvador
Institute/School/College
Knowledge Area
Date of Defense
Published
São Paulo, 2009
Supervisor
Committee
Hamada, Margarida Mizue (President)
Dantas, Carlos Costa
Lopes, Ricardo Tadeu
Mesquita, Carlos Henrique de
Park, Song Won
Title in Portuguese
Análise de sistemas multifásicos utilizando tomografia computadorizada Gama monoenergética e polienergética
Keywords in Portuguese
bioreator
CARPT
CT
gama
hidrodinâmica
holdup
monolítico
multifásicos
reator
reconstrução de imagens
Tomografia
Abstract in Portuguese
A tecnologia de reatores multifásicos é o coração das transformações químicas de todos os processos industriais, concretamente 99% dos reatores trabalham com a presença de uma ou mais fases. A tomografia é uma técnica poderosa capaz de determinar o efeito de parâmetros operacionais e de desenho na distribuição do holdup das fases, visualizando sistemas opacos de uma forma não invasiva. Um tomógrafo computadorizado de fonte única (SSCT) com capacidade de gerar imagens para as distribuições de holdup em sistemas com duas fases dinâmicas foi desenvolvido e validado com sucesso no CTR/IPEN. Algoritmos para reconstrução de imagens analíticos e discretos ou iterativos (estatísticos) foram desenvolvidos e implementados para tais aplicações e depois comparados. O SSCT foi utilizado para determinar as distribuições de porosidades e de holdup dos sólidos para uma coluna de recheio aleatório. Na Washington University em St. Louis, no Laboratório de Engenharia da Reação Química (CREL), um tomógrafo com duas fontes radioativas (DSCT) capaz de gerar imagens da distribuição do holdup das fases para sistemas dinâmicos com três fases móveis foi validado com êxito. Uma nova metodologia para reconstrução de imagens, que garantiu alta precisão na geração das distribuições do holdup em sistemas de grande porte, foi aplicada. O DSCT permitiu avaliar a influência de parâmetros de operação e do desenho de um aerador em um bioreator na escala piloto. O efeito do desenho de um distribuidor de gás líquido e do regime de escoamento foram determinados para um reator monolítico utilizando o DSCT. Os equipamentos e técnicas desenvolvidas neste trabalho podem ser considerados como uma ferramenta efetiva de pesquisa, intensificando estudos experimentais em uma grande gama de sistemas multifásicos através de geração de imagens. Para isto, foram superadas várias limitações comuns a outras técnicas tomográficas existentes utilizadas no estudo de sistemas com duas e três fases dinâmicas, onde os conhecimentos adquiridos nestes estudos poderão melhorar a compreensão básica dos efeitos de desenho e dinâmica em reatores multifásicos.
Title in English
MONOENERGETIC AND POLYENERGETIC GAMMA RAY COMPUTER TOMOGRAPHY FOR MULTIPHASE SYSTEMS ANALYSIS
Keywords in English
bioreator
CARPT
CT
gama
hidrodinâmica
holdup
monolítico
multifásicos
reator
reconstrução de imagens
Tomografia
Abstract in English
It is important to recognize that at the heart of chemical transformations in all process and energy industries is multiphase reator technology, as over 99% of reator systems require the presence of more than one phase for proper operation. Tomography is a powerful technique capable of determining the effect of operating and design parameters on the phase holdup distribution by visualization in opaque flow systems in a noninvasive manner. A single source computed tomography (SSCT) system capable of imaging phase holdup distribution in two phases flow was successfully developed and validated at CTR/IPEN. Analytical and discrete (statistical) image reconstruction algorithms were developed and compared between them. SSCT has been applied to characterize the gas holdup and porosity distributions in a random packed column. At the Chemical Reaction Engineering Laboratory (CREL) of Washington University in St Louis, a novel dual source computed tomography (DSCT) system capable of imaging phase holdup distribution in three phases flow was successfully developed and validated. A new image reconstruction methodology was applied for the image reconstruction of the DSCT which enables accurate imaging of the phase holdup distribution in large scale multiphase systems. DSCT has been applied to characterize the effect of operating parameters and sparger design on the liquid flow behavior of a pilot scale anaerobic bioreactor. Performance studies were carried to access the performance of a gas-liquid distributor and liquid flow in a monolithic reactor using the DSCT. The scanners and techniques developed as part of this work provides an effective research tool for expanding experimental research in a wide range of multiphase flow systems via imaging. It has overcome many limitations, common to the various tomography techniques that exist for imaging systems with two and three phase flow. The knowledge gained from these studies improves the fundamental understanding of the effects of design and dynamics of multiphase reactors.
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.
Publishing Date
2009-11-27
 
WARNING: Learn what derived works are clicking here.
All rights of the thesis/dissertation are from the authors
CeTI-SC/STI
Digital Library of Theses and Dissertations of USP. Copyright © 2001-2024. All rights reserved.