• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Tese de Doutorado
DOI
https://doi.org/10.11606/T.85.2011.tde-09052012-150636
Documento
Autor
Nome completo
Vanderlei Cardoso
E-mail
Unidade da USP
Área do Conhecimento
Data de Defesa
Imprenta
São Paulo, 2011
Orientador
Banca examinadora
Dias, Mauro da Silva (Presidente)
Bitelli, Ulysses D'Utra
Figueiredo, Ana Maria Graciano
Helene, Otaviano Augusto Marcondes
Maidana, Nora Lia
Título em português
Estudo das covariâncias envolvidas no método k0 de análise por ativação neutrônica
Palavras-chave em português
análise
ativação
covariâncias
k0
neutrônica
Resumo em português
O presente trabalho se propôs ao desenvolvimento de uma metodologia para o tratamento das incertezas do método k0 de Análise por Ativação Neutrônica (AAN), de forma abrangente e acurada, aplicando a metodologia de Análise por Covariâncias. Todos os parâmetros envolvidos na determinação da concentração de um elemento estudado foram analisados de forma criteriosa, estabelecendo as correlações entre eles. Também foram estabelecidas as possíveis correlações entre as concentrações de elementos diferentes, para a mesma amostra e em amostras diferentes. Este procedimento gerou um número grande de correlações que foram tratadas rigorosamente. Os dados para análise foram obtidos experimentalmente, por meio de irradiações efetuadas na posição de irradiação 24A próxima ao núcleo do reator de pesquisas IEA-R1 do IPEN-CNEN/SP. Os parâmetros α e ƒ, de caracterização do campo neutrônico, foram determinados, aplicando-se vários métodos apresentados na literatura. Um tratamento estatístico detalhado foi aplicado a cada uma das medidas, verificando-se as diversas incertezas parciais e suas correlações. Com o objetivo de aprofundar o estudo, foram escolhidos os alvos de 64Zn e 68Zn, para os quais foram determinados experimentalmente os parâmetros nucleares k0 e Q0, que apresentavam discrepâncias na literatura. Os valores destes parâmetros para o 64Zn resultaram 5,63(8) × 10-3 e 1,69(6), respectivamente. Para o 68Zn, resultaram 4,00(6) × 10-4 e 2,34(4), respectivamente. Estes valores foram comparados com os dados existentes na literatura. O método de Monte Carlo foi aplicado em diversas fases do estudo, para permitir a determinação acurada de alguns parâmetros, necessários para a análise completa dos dados.
Título em inglês
Study of covariances involved in the k0 method of neutron activation analysis
Palavras-chave em inglês
activation
analysis
covariances
k0
neutron
Resumo em inglês
This work aimed the development of a methodology for the treatment of uncertainty in the k0 Method for Neutron Activation Analysis (NAA), comprehensively and accurately, by applying the covariance analysis methodology. All parameters involved in determining the concentration of a given element were analyzed with criteria in order to establish the correlations among them. Also established were the possible correlations between the concentrations of different elements for the same sample and for different samples. This procedure generated a large number of correlations that have been rigorously addressed. Data for analysis were obtained experimentally by means of irradiations performed at 24A irradiation position, near the core of the IEA-R1 research reactor, located at IPEN-CNEN/SP. The parameters α and ƒ, characterizing the neutron field were determined by applying several methods from the literature. A detailed statistical treatment was applied to each measurement, verifying the various uncertainties and partial correlations. In order to deepen the study, targets of 64Zn and 68Zn were chosen, for which the nuclear parameters k0 and Q0 showed discrepancies in the literature in order to determine them experimentally. For 64Zn, the values for these parameters resulted 5.63(8) × 10-3 and 1.69(6), respectively. For 68Zn they resulted 4.00(6) × 10-4 and 2.34(4), respectively. These values were compared with data from the literature. The Monte Carlo method was applied at various stages of study, to allow accurate determination of some parameters needed for the complete data analysis.
 
AVISO - A consulta a este documento fica condicionada na aceitação das seguintes condições de uso:
Este trabalho é somente para uso privado de atividades de pesquisa e ensino. Não é autorizada sua reprodução para quaisquer fins lucrativos. Esta reserva de direitos abrange a todos os dados do documento bem como seu conteúdo. Na utilização ou citação de partes do documento é obrigatório mencionar nome da pessoa autora do trabalho.
2011CardosoEstudo.pdf (2.57 Mbytes)
Data de Publicação
2012-05-30
 
AVISO: Saiba o que são os trabalhos decorrentes clicando aqui.
Todos os direitos da tese/dissertação são de seus autores
CeTI-SC/STI
Biblioteca Digital de Teses e Dissertações da USP. Copyright © 2001-2024. Todos os direitos reservados.