• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Disertación de Maestría
DOI
https://doi.org/10.11606/D.85.2018.tde-09022018-083115
Documento
Autor
Nombre completo
Cássia Yumi Furukawa
Dirección Electrónica
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
São Paulo, 2016
Director
Tribunal
Matsuda, Margareth Mie Nakamura (Presidente)
Colturato, Maria Tereza
Oliveira Junior, Vani Xavier de
Título en portugués
Avaliação de alguns fatores interferentes na estabilidade radioquímica de alguns radiofármacos marcados com 99mTc
Palabras clave en portugués
estabilidade de transporte
pureza radioquímica
radiofármaco
Resumen en portugués
Os radiofármacos são fármacos que possuem em sua composição um radionuclídeo e são utilizados para diagnóstico e tratamento de diversas doenças na medicina nuclear. O principal objetivo desse trabalho foi avaliar o efeito da temperatura e umidade na estabilidade de alguns reagentes liofilizados ALBUMINA-TEC, CIS-TEC, DEX-500-TEC, DEX-70-TEC, DISI-TEC, DMSA-TEC, DTPA-TEC, FITA-TEC, PUL-TEC, MIBI-TEC, MDP-TEC, PIRO-TEC, e TIN-TEC. Foi utilizada uma câmara climática para expor amostras destes produtos a uma temperatura de 40 °C e 75% de umidade relativa por 48 horas, para simular uma condição de transporte. Foram avaliadas duas situações: após um determinado tempo de armazenamento em temperatura de 2 - 8 °C, amostras de RL foram expostas por 48 horas em 40 °C e 75% UR e em seguida foram analisadas enquanto outras amostras foram colocadas por 48 horas em 40 °C e 75% UR, mantidas em temperatura de 2 - 8 °C até a validade do radiofármaco e analisadas quanto à pureza radioquímica e biodistribuição. Os radiofármacos ALBUMINA-TEC, DEX-70-TEC, DEX-500-TEC, DISI-TEC, DMSA-TEC, DTPA-TEC, PIRO-TEC, MDP-TEC, MIBI-TEC e MDP-TEC apresentaram resultados de % PRq e biodistribuição que atenderam às especificações, enquanto que CIS-TEC, PUL-TEC e TIN-TEC apresentaram alguns valores de % PRq menor que o especificado. TIN-TEC apresentou % PRq de 84% em um de três lotes, enquanto PUL-TEC apresentou % PRq de 88% em um de quatro lotes analisados; CIS-TEC é um RL que ainda precisa melhor analisado pois os resultados fora do especificado no controle radioquímico e biológico foram obtidos com um produto fora da validade especificada. Estes resultados indicaram que a pureza radioquímica pode ser afetada pela condição de estudo, o que não foi confirmado pelo controle biológico.
Título en inglés
Evaluation of some interfering factors on the radiochemical stability of some radiopharmaceuticals labeled Technetium-99m
Palabras clave en inglés
radiochemical purity
radiopharmaceutical
transport stability
Resumen en inglés
Radiopharmaceuticals are pharmaceuticals that have in their composition a radionuclide and are used for diagnosis and treatment of various diseases in nuclear medicine. The main objective of this study was to evaluate the effect of temperature and humidity on the stability of some lyophilized reagents: ALBUMINA-TEC, CIS-TEC, DEX-500-TEC, DEX-70-TEC, DISI-TEC, DMSA-TEC, DTPA-TEC, FITA-TEC, PUL-TEC, MIBI-TEC, MDP-TEC, PIRO-TEC and TIN-TEC. A climatic chamber was used for exposing some samples of these products to a temperature of 40 °C and 75% RH for 48 hours to simulate a transport condition. Two situations were evaluated: after a certain storage time at 2 - 8 °C, LR samples were exposed for 48 hours at 40 °C and 75% RH and analyzed while other samples were placed for 48 hours at 40 °C and 75% RH, kept at 2 - 8 °C until the expiration time of each radiopharmaceutical and analyzed for radiochemical purity and biodistribution. ALBUMINA-TEC, DEX-70-TEC, DEX-500-TEC, DISI-TEC, DMSA-TEC, DTPA-TEC, PIRO-TEC, MDP-TEC, MIBI-TEC and MDP-TEC presented results of % RCP and biodistribution that met the specifications while CIS-TEC PUL-TEC and TIN-TEC presented some % RCP lower than specified. TIN-TEC presented % RCP of 84% in one of three lots while PUL-TEC presented % RCP of 88% in a one of four batches analyzed; CIS-TEC is a LR that further need to be analyzed because probable the out of specification results of radiochemical and biological controls were obtained with a product outside of the validity date. These results indicated that radiochemical purity, can be affected by study condition, which has not been confirmed by biological control.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Fecha de Publicación
2018-03-06
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.