Rodrigues, Letícia Lucente Campos (Presidente)
Poli, Maria Esmeralda Ramos
Rocha, Felícia Del Gallo
Título en portugués
Avaliação do desempenho dos detectores termoluminescentes de CaSO4:Dy e LiF:Mg, Ti na dosimetria de feixes clínicos de elétrons
Palabras clave en portugués
dosimetria de elétrons
Dosímetro Termoluminescente
radioterapia
Resumen en portugués
A avaliação do desempenho dos detectores termoluminescentes de CaSO4:Dy, produzidos pelo IPEN, tem como objetivo apresentar uma alternativa aos dosímetros de LiF:Mg,Ti comerciais (TLD-100), amplamente empregados em radioterapia, na dosimetria de feixes clínicos de elétrons. Os dois tipos de detectores termoluminescentes foram caracterizados, com a utilização de objetos simuladores de PMMA, água sólida do tipo RMI-457 e água, em campos de radiação de elétrons de 4, 6, 9, 12 e 16 MeV de energias nominais, nos quais as curvas de dose-resposta foram obtidas e as doses superficial e profunda foram determinadas. A dependência da resposta termoluminescente com a energia nominal dos elétrons e com o objeto simulador empregado foram estudadas. O CaSO4:Dy apresentou o mesmo comportamento do LiF:Mg,Ti; de maneira que sua aplicação como uma alternativa às pastilhas TLD-100 na dosimetria de feixes de elétrons em radioterapia é viável e apresenta a sensibilidade à radiação de elétrons significativamente mais alta como principal vantagem.
Título en inglés
ASSESSMENT OF CaSO4:Dy AND LiF:Mg,Ti THERMOLUMINESCENT DOSIMETERS PERFORMANCE IN THE DOSIMETRY OF CLINICAL ELECTRON BEAM
Palabras clave en inglés
dosimetria de elétrons
Dosímetro termoluminescente
radioterapia
Resumen en inglés
The assessment of the performance of CaSO4:Dy thermoluminescent detectors produced by IPEN in the dosimetry of clinical electron beams aims to propose an alternative to the LiF:Mg,Ti commercial dosimeters (TLD-100) largely applied in radiation therapy. The two types of thermoluminescent dosimeters were characterised with the use of PMMA, RMI-457 type solid water and water phantoms in radiation fields of 4, 6, 9, 12 and 16 MeV electrons of nominal energies in which the dose-response curves were obtained and the surface and depth doses were determined. The thermoluminescent response dependency with the electron nominal energies and the applied phantom were studied. The CaSO4:Dy presented the same behaviour than the LiF:Mg,Ti in such a way that its application as an alternative to the TLD-100 pellets in the radiation therapy dosimetry of electron beams is viable and presents the significantly higher sensitivity to the electron radiation as its main advantage.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
MairaGoesNunes.pdf (1.79 Mbytes)
Fecha de Publicación
2009-09-23
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.