• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Disertación de Maestría
DOI
https://doi.org/10.11606/D.85.2017.tde-07122017-113255
Documento
Autor
Nombre completo
Amanda Noyori
Dirección Electrónica
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
São Paulo, 2017
Director
Tribunal
Saiki, Mitiko (Presidente)
Ribeiro, Andreza Portella
Sumita, Nairo Massakazu
Título en portugués
Estudo sobre determinação de alumínio em amostras ambientais pelo método de análise por ativação com nêutrons
Palabras clave en portugués
alumínio
amostras ambientais
análise por ativação com nêutrons
reações nucleares de interferência
Resumen en portugués
As determinações de alumínio são de grande interesse devido à sua toxicidade e sua ampla distribuição no meio ambiente. Além disso as determinações deste elemento por métodos analíticos convencionais apresentam dificuldades devido aos problemas da contaminação da amostra. O método de análise por ativação com nêutrons (NAA) para determinação de Al possui vantagens de rapidez na análise e de alta sensibilidade. Entretanto, neste método ocorrem os problemas de reações nucleares de interferência de P e Si. O Al na NAA é determinado pela medida do 28Al formado na reação 27Al (n, γ) 28Al, o mesmo radioisótopo formado nas reações nucleares 31P (n, α) 28Al e 28Si (n, p) 28Al. O objetivo deste estudo foi determinar Al pela NAA em amostras ambientais, fazendo a correção das interferências usando fatores de correção e dispondo das concentrações de P e de Si das amostras. Neste estudo foram analisados os materiais de referência certificados (MRCs) e amostras de biomonitores (cascas de árvore e líquen). O procedimento experimental consistiu na irradiação curta de uma alíquota de amostra no reator IEA-R1 juntamente com o padrão de Al, seguida de espectrometria de raios gama. O P foi determinado pela medida da radiação beta do 32P usando um contador Geiger-Müller. O Si foi determinado por meio da irradiação com nêutrons epitérmicos e medida do 29Al formado na reação 29Si (n,p) 29Al. Os resultados da determinação de Al, P e Si nos MRCs apresentaram uma boa precisão e exatidão com |Z-score| ≤ 2. As concentrações de Al obtido nos biomonitores variaram de 253 a 15783 μg g-1 e no caso da determinação de P e Si as concentrações destes elementos variaram de 283 a 1946 μg g-1 e de 0,11 a 7,8 %, respectivamente. Nos biomonitores analisados, as taxas de contribuição de interferência de P e de Si na determinação de Al foram da ordem de 2,0 % e esta contribuição depende das relações entre as concentrações dos interferentes e a do Al na amostra. Os limites de detecção de Al na análise dos biomonitores foram inferiores às suas concentrações demonstrando que procedimento de NAA proposto pode ser aplicado na determinação de Al neste tipo de matriz.
Título en inglés
A study on aluminum determination in environmental samples by neutron activation analysis
Palabras clave en inglés
aluminum
environmental samples
interference nuclear reactions
neutron activation analysis
Resumen en inglés
Aluminum determinations are of great interest since this element is toxic to humans and it is widely distributed in the environment. Besides, the determinations of this element by conventional analytical methods present difficulties due to sample contamination during the analyses. Neutron activation analysis (NAA) for Al determination presents advantages of fast analyses and of high sensitivity. However, NAA of Al does present problems of P and Si nuclear reaction interferences. Aluminum is determined by measuring 28Al, formed in the reaction 27Al (n, γ) 28Al, the same radioisotope formed in reactions 31P (n, α) 28Al and 28Si (n, p) 28Al. The purpose of this study was to determine Al in environmental samples by NAA correcting these interferences using correction factors, and determining P and Si concentrations in the samples. In this study, certified reference materials and biomonitor samples (tree barks and lichen) were analyzed. Experimental procedure consisted of irradiating an aliquot of the sample at the IEA-R1 nuclear research reactor together with Al standard, followed by gamma ray spectrometry. Phosphorus was determined by measuring beta radiation of 32P using a Geiger-Müller counter. Silicon was determined by epithermal neutron activation analysis and measuring 29Al formed in the reaction 29Si (n, p)29Al. Results obtained in the determination of Al, P and Si in the certified reference materials showed good precision and accuracy with |Z-score| ≤ 2. Aluminum results in the biomonitor samples varied from to 253 to 15783 μg g-1. In the case of P its concentrations varied from 283 to 1946 μg g-1. Silicon determinations in biomonitors varied from 0.11 to 7.8 %. The interference contribution rates in the analyses of the biomonitor samples were of the order of 2.0 % and this contribution depends on the relation between concentrations of interfering elements and of Al in the sample. Detection limit values of Al in the biomonitor analyses were lower than their concentrations in the samples demonstrating that the proposed procedure of NAA can be applied in the Al determination in this kind of matrix.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
2017NoyoriEstudo.pdf (2.07 Mbytes)
Fecha de Publicación
2017-12-28
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.