Mémoire de Maîtrise
DOI
https://doi.org/10.11606/D.85.2013.tde-07022014-095250
Document
Auteur
Nom complet
Leonardo de Holanda Mencarini
Adresse Mail
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
São Paulo, 2013
Directeur
Jury
Caldas, Linda Viola Ehlin (Président)
Caldeira, Alexandre David
Federico, Claudio Antonio
Titre en portugais
Estudo do comportamento de um detector de radiação passivo para fins aeronáuticos utilizando o método Monte Carlo
Mots-clés en portugais
detector
equivalente de dose ambiente
Método Monte Carlo
Resumé en portugais
Profissionais da área aeronáutica, como pilotos e comissários de bordo, são submetidos a doses de radiação de origem cósmica, que podem ser maiores do que as doses médias dos trabalhadores da indústria nuclear. A diversidade de partículas de altas energias presentes no campo de radiação a bordo das aeronaves torna complexa a mensuração da dose e requer cuidados especiais em relação aos sistemas de dosimetria a serem empregados nesta área. A Força Aérea Brasileira, por meio de seu Instituto de Estudos Avançados (IEAv /DCTA), em conjunto com o Instituto de Pesquisas Energéticas e Nucleares (IPEN / CNEN -SP) vem estudando o assunto desde 2008. Um protótipo de detector de radiação passivo para medições em aeronaves foi previamente construído e testado em condições de voo e de laboratório. O detector é capaz de medir a grandeza dosimétrica conhecida como dose absorvida (usando dosímetros passivos), que serão posteriormente correlacionados ao equivalente de dose ambiente e à dose efetiva recebidos por profissionais da área aeronáutica. Neste contexto, uma abordagem teórica por meio de simulações Monte Carlo com os códigos computacionais MCNP5 e MCNPX, foi usada para modelar e caracterizar a resposta do detector em determinadas condições experimentais. Este trabalho apresenta os resultados preliminares da modelagem computacional, com ênfase especial na comparação entre a grandeza fundamental dose absorvida (mensurada e simulada) e sua relação com o equivalente de dose ambiente e dose efetiva para este detector.
Titre en anglais
Performance study of a passive radiation detector for aviation purposes using the Monte Carlo Method
Mots-clés en anglais
ambient dose equivalent
detector
Monte Carlo Method
Resumé en anglais
Aircrews, as pilots and flight attendants, are subjected to cosmic ray doses which can be higher than the average doses on workers from the nuclear industry. The diversity of particles of high energies present in the radiation field on board of aircrafts, turns the determination of the incident dose and requires special care regarding dosimetric systems to be used in this kind of field. The Brazilian Air Force, through the Institute for Advanced Studies (Instituto de Estudos Avançados, IEAv/DCTA) in conjunction with the Institute of Energetic and Nuclear Research (Instituto de Pesquisas Energéticas e Nucleares IPEN/CNEN-SP) are working on this subject since 2008. A prototype of a radiation detector for aircraft measurements was previously built and tested in flight and laboratory conditions. The detector is able of measuring a quantity known as absorbed dose (using passive dosimeters), which will subsequently be correlated to the ambient dose equivalent and the effective dose received by aircrews. In this context, a theoretical approach through Monte Carlo simulations with the computational codes MCNP5 and MCNPX was used to model and characterize the detector response at such experimental conditions. This work presents the preliminary results of the computational modeling, with special emphasis on the comparison between the absorbed dose quantity (measured and simulated) and its relationship with the ambient dose equivalent and the effective Dose for this detector.
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
Date de Publication
2014-02-18
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.