Título em português
Projeto e implementação do equipamento para tomografia com nêutrons do IPEN-CNEN/SP
Palavras-chave em português
imageamento com nêutrons
nêutrons
tomografia com nêutrons
Resumo em português
Na presente dissertação, foi desenvolvido um equipamento para tomografia com nêutrons que está operacional e instalado no canal de irradiação 14 do Reator Nuclear de Pesquisas IEA-R1 do IPEN-CNEN/SP. As imagens apresentadas neste trabalho, são de objetos que foram selecionados de modo a realçarem uma das principais aplicações da técnica, que é o estudo de materiais hidrogenados mesmo se envoltos por espessa camada de alguns metais. Neste equipamento, uma tomografia completa pode ser obtida em 400 s, com uma resolução espacial máxima de 205 μm. Estas características são comparáveis às dos equipamentos mais desenvolvidos em operação em outros países, e propiciam imagens com qualidade suficiente para que sejam realizadas análises tanto qualitativas quanto quantitativas dos objetos inspecionados. A implementação da técnica da tomografia com nêutrons abre a possibilidade de novas linhas de pesquisa, pois disponibiliza uma nova ferramenta para inspeção de objetos, que fornece uma visão da sua estrutura interna, que nem sempre é possível por métodos de imageamento bidimensional.
Título em inglês
Design and development of a neutron tomography facility at the IPEN-CNEN/SP
Palavras-chave em inglês
neutron
neutron imaging
neutron tomography
Resumo em inglês
In the work reported in this dissertation, a facility for neutron tomography was developed and installed at the irradiation channel #14 of the IEA-R1 nuclear research reactor of IPEN-CNEN/SP. Several selected objects were inspected, and the obtained images demonstrate the main characteristic of the present technique that is its capability to visualize hydrogenous rich substances. In such facility, a tomography can be obtained in 400 s with a spatial resolution of 205 μm, and the obtained images have sufficient quality to allow qualitative and quantitative analysis. These characteristics are very similar to the ones of the top facilities around the world, and the quality of the provided images are sufficient to allow qualitative and quantitative analysis of the inspected object. The implementation of the neutron tomography technique opens up the possibility of new research as it provides a new tool for inspection of objects, which provides a view of its internal structure, which is not always possible for two-dimensional imaging methods.
 
AVISO - A consulta a este documento fica condicionada na aceitação das seguintes condições de uso:
Este trabalho é somente para uso privado de atividades de pesquisa e ensino. Não é autorizada sua reprodução para quaisquer fins lucrativos. Esta reserva de direitos abrange a todos os dados do documento bem como seu conteúdo. Na utilização ou citação de partes do documento é obrigatório mencionar nome da pessoa autora do trabalho.
Data de Publicação
2016-05-06
 
AVISO: Saiba o que são os trabalhos decorrentes clicando aqui.
Todos os direitos da tese/dissertação são de seus autores
CeTI-SC/STI
Biblioteca Digital de Teses e Dissertações da USP. Copyright © 2001-2024. Todos os direitos reservados.