Mémoire de Maîtrise
DOI
https://doi.org/10.11606/D.85.2009.tde-05112009-102509
Document
Auteur
Nom complet
Christianne Cobello Cavinato
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
São Paulo, 2009
Directeur
Jury
Rodrigues, Letícia Lucente Campos (Président)
Furquim, Tânia Aparecida Correia
Rocha, Felícia Del Gallo
Titre en portugais
Padronização do método de dosimetria Fricke gel e avaliação tridimensional de dose empregando a técnica de imageamento por ressonância magnética
Mots-clés en portugais
Dosimetria Fricke gel
gelatina 270 Bloom
Imageamento por ressonância magnética (IRM).
Resumé en portugais
Neste trabalho foi padronizado o método de obtenção da solução Fricke gel desenvolvida no IPEN. Foram comparados os resultados obtidos para diferentes qualidades do gel utilizado na preparação das soluções e a influência da concentração de gelatina na resposta das soluções dosimétricas. Testes de desempenho tais como: resposta em função da dose, limites mínimo e máximo de detecção, reprodutibilidade da resposta, entre outros, foram realizados utilizando diferentes tipos de radiação e empregando as técnicas de espectrofotometria de Absorção Óptica (AO) e Ressonância Magnética (RM). Os intervalos de dose determinados para radiação gama do Co 60 e fótons de 6 MeV estão entre 0,4 e 30,0 Gy e entre 0,5 e 100,0 Gy , empregando as técnicas de AO e RM, respectivamente. Um estudo de difusão dos íons férricos na solução foi realizado para a determinação do intervalo de tempo ótimo entre a irradiação e a avaliação das amostras; as imagens por RM podem ser obtidas com boa nitidez até 2,5 horas após a irradiação. Também foi desenvolvido um simulador esférico constituído de solução Fricke gel preparada com 5% de gelatina 270 Bloom (qualidade nacional), para a avaliação tridimensional de dose empregando a técnica de Imageamento por Ressonância Magnética (IRM). A solução Fricke gel preparada com gelatina 270 Bloom , que, além do baixo custo, pode ser adquirida facilmente no mercado nacional, apresenta resultados satisfatórios quanto à facilidade de manuseio, sensibilidade, reprodutibilidade da resposta e consistência. Os resultados obtidos confirmam sua aplicabilidade na dosimetria tridimensional pela técnica de IRM.
Titre en anglais
STANDARDIZATION OF THE FRICKE GEL DOSIMETRY METHOD AND TRIDIMENSIONAL DOSE EVALUATION USING THE MAGNETIC RESONANCE IMAGING TECHNIQUE
Mots-clés en anglais
Dosimetria Fricke gel
gelatina 270 Bloom
Imageamento por Ressonância Magnética (IRM).
Resumé en anglais
This study standardized the method for obtaining the Fricke gel solution developed at IPEN. The results for different gel qualities used in the preparation of solutions and the influence of the gelatin concentration in the response of dosimetric solutions were compared. Type tests such as: dose response dependence, minimum and maximum detection limits, response reproducibility, among others, were carried out using different radiation types and the Optical Absorption (OA) spectrophotometry and Magnetic Resonance (MR) techniques. The useful dose ranges for Co 60 gamma radiation and 6 MeV photons are 0,4 to 30,0 Gy and 0,5 to 100,0 Gy , using OA and MR techniques, respectively. A study of ferric ions diffusion in solution was performed to determine the optimum time interval between irradiation and samples evaluation; until 2,5 hours after irradiation to obtain sharp MR images. A spherical simulator consisting of Fricke gel solution prepared with 5% by weight 270 Bloom gelatine (national quality) was developed to be used to three-dimensional dose assessment using the Magnetic Resonance Imaging (MRI) technique. The Fricke gel solution prepared with 270 Bloom gelatine, that, in addition to low cost, can be easily acquired on the national market, presents satisfactory results on the ease of handling, sensitivity, response reproducibility and consistency. The results confirm their applicability in the threedimensional dosimetry using MRI technique.
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.