• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Master's Dissertation
DOI
https://doi.org/10.11606/D.85.2009.tde-05112009-102509
Document
Author
Full name
Christianne Cobello Cavinato
Institute/School/College
Knowledge Area
Date of Defense
Published
São Paulo, 2009
Supervisor
Committee
Rodrigues, Letícia Lucente Campos (President)
Furquim, Tânia Aparecida Correia
Rocha, Felícia Del Gallo
Title in Portuguese
Padronização do método de dosimetria Fricke gel e avaliação tridimensional de dose empregando a técnica de imageamento por ressonância magnética
Keywords in Portuguese
Dosimetria Fricke gel
gelatina 270 Bloom
Imageamento por ressonância magnética (IRM).
Abstract in Portuguese
Neste trabalho foi padronizado o método de obtenção da solução Fricke gel desenvolvida no IPEN. Foram comparados os resultados obtidos para diferentes qualidades do gel utilizado na preparação das soluções e a influência da concentração de gelatina na resposta das soluções dosimétricas. Testes de desempenho tais como: resposta em função da dose, limites mínimo e máximo de detecção, reprodutibilidade da resposta, entre outros, foram realizados utilizando diferentes tipos de radiação e empregando as técnicas de espectrofotometria de Absorção Óptica (AO) e Ressonância Magnética (RM). Os intervalos de dose determinados para radiação gama do Co 60 e fótons de 6 MeV estão entre 0,4 e 30,0 Gy e entre 0,5 e 100,0 Gy , empregando as técnicas de AO e RM, respectivamente. Um estudo de difusão dos íons férricos na solução foi realizado para a determinação do intervalo de tempo ótimo entre a irradiação e a avaliação das amostras; as imagens por RM podem ser obtidas com boa nitidez até 2,5 horas após a irradiação. Também foi desenvolvido um simulador esférico constituído de solução Fricke gel preparada com 5% de gelatina 270 Bloom (qualidade nacional), para a avaliação tridimensional de dose empregando a técnica de Imageamento por Ressonância Magnética (IRM). A solução Fricke gel preparada com gelatina 270 Bloom , que, além do baixo custo, pode ser adquirida facilmente no mercado nacional, apresenta resultados satisfatórios quanto à facilidade de manuseio, sensibilidade, reprodutibilidade da resposta e consistência. Os resultados obtidos confirmam sua aplicabilidade na dosimetria tridimensional pela técnica de IRM.
Title in English
STANDARDIZATION OF THE FRICKE GEL DOSIMETRY METHOD AND TRIDIMENSIONAL DOSE EVALUATION USING THE MAGNETIC RESONANCE IMAGING TECHNIQUE
Keywords in English
Dosimetria Fricke gel
gelatina 270 Bloom
Imageamento por Ressonância Magnética (IRM).
Abstract in English
This study standardized the method for obtaining the Fricke gel solution developed at IPEN. The results for different gel qualities used in the preparation of solutions and the influence of the gelatin concentration in the response of dosimetric solutions were compared. Type tests such as: dose response dependence, minimum and maximum detection limits, response reproducibility, among others, were carried out using different radiation types and the Optical Absorption (OA) spectrophotometry and Magnetic Resonance (MR) techniques. The useful dose ranges for Co 60 gamma radiation and 6 MeV photons are 0,4 to 30,0 Gy and 0,5 to 100,0 Gy , using OA and MR techniques, respectively. A study of ferric ions diffusion in solution was performed to determine the optimum time interval between irradiation and samples evaluation; until 2,5 hours after irradiation to obtain sharp MR images. A spherical simulator consisting of Fricke gel solution prepared with 5% by weight 270 Bloom gelatine (national quality) was developed to be used to three-dimensional dose assessment using the Magnetic Resonance Imaging (MRI) technique. The Fricke gel solution prepared with 270 Bloom gelatine, that, in addition to low cost, can be easily acquired on the national market, presents satisfactory results on the ease of handling, sensitivity, response reproducibility and consistency. The results confirm their applicability in the threedimensional dosimetry using MRI technique.
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.
Publishing Date
2009-11-27
 
WARNING: Learn what derived works are clicking here.
All rights of the thesis/dissertation are from the authors
CeTI-SC/STI
Digital Library of Theses and Dissertations of USP. Copyright © 2001-2024. All rights reserved.