Master's Dissertation
DOI
https://doi.org/10.11606/D.85.2006.tde-04062007-163758
Document
Author
Full name
Audrew Frimaio
Institute/School/College
Knowledge Area
Date of Defense
Published
São Paulo, 2006
Supervisor
Committee
Rodrigues, Letícia Lucente Campos (President)
Nersissian, Denise Yanikian
Potiens, Maria da Penha Albuquerque
Title in Portuguese
"Desenvolvimento de um material cerâmico para utilização em proteção radiológica diagnóstica"
Keywords in Portuguese
Blindagem
Material cerâmico
Proteção radiológica
Abstract in Portuguese
Este estudo tem por objetivo formular um composto cerâmico para revestimento de paredes visando contribuir para a otimização da blindagem de salas de diagnóstico. O trabalho foi baseado em medidas experimentais de atenuação da radiação X (80 e 100 kV) empregando materiais cerâmicos de revestimento contendo diferentes suportes cerâmicos (vermelho, branco, grês, porcelanatos, etc). Dentre os suportes cerâmicos avaliados, o grês branco apresentou melhores propriedades atenuadoras, e foi considerado o mais adequado para a proposta deste trabalho. Diferentes formulações de grês branco foram estudadas e alteradas a fim de obter melhores propriedades atenuadoras. Foram efetuadas simulações de composições cerâmicas de revestimento grês dentro das porcentagens de matérias-primas necessárias na composição que são 12-20% argila; 6-18% caulim; 12-25% filito; 8-14% quartzo; 10-18% feldspato; 32- 40% pegmatito; 6-8% talco. As composições químicas quantitativas e qualitativas destes materiais foram também avaliadas, e os elementos constituintes mais comuns são SiO2, Fe2O3, Al2O3, CaO e Ti2O3. Considerando que o CaO pode ser substituído pelo PbO ou BaO, foram estudadas formulações com maiores teores de óxidos de Pb e Ba. O comportamento destes materiais como atenuadores para a radiação X foi investigado por meio de simulações computacionais que levaram em consideração os espectros de raios X incidentes e transmitidos através das diferentes composições estudadas e comparado com os materiais de referência Pb, Ba e BaSO4 (barita). Os resultados obtidos nas simulações indicaram as formulações do composto de suporte cerâmico grês que demonstram melhores propriedades de atenuação levando-se em conta as energias usadas em raios X diagnóstico (80, 100 e 150 kV). Placas cerâmicas baseadas na composição formulada que apresentou menor diferença percentual em relação ao Pb foram produzidas em laboratório e testadas fisicamente como revestimento de parede e barreira protetora. Propriedades como módulo de resistência à flexão, densidade, carga de ruptura, absorção de água e atenuação da radiação X foram avaliadas para todas as placas produzidas.
Title in English
DEVELOPMENT OF A CERAMIC MATERIAL TO COVER WALLS TO BE APPLIED IN DIAGNOSTIC RADIOLOGICAL PROTECTION
Keywords in English
ceramic material
radiological protection
shield
Abstract in English
This study aims to formulate a ceramic composition for wall coating seeking to contribute to the optimization of diagnosis rooms’ shielding. The work was based on experimental measures of X-radiation attenuation (80 and 100 kV) using ceramic coating materials containing different ceramic bases (red, white, grês, stoneware porcelain tiles, etc). Among the appraised ceramic bases, the white grês presented better attenuation properties and it was considered the most suitable material for the targets of this work. Different formulations of white grês were studied and altered in order to obtain better attenuation properties. Simulations of ceramic compositions using grês coating were made maintaining the percentages of 12-20% clay; 6-18% kaolin; 12-25% phyllite; 8-14% quartz; 10- 18% feldspar; 32-40% pegmatite and 6-8% talc in the composition of the necessary raw-material. The quantitative and qualitative chemical compositions of these materials were also evaluated and the most common representative elements are SiO2, Fe2O3, Al2O3, CaO and Ti2O3. Formulations containing Pb and Ba oxides were studied, considering that CaO can be replaced by PbO or BaO. The attenuation properties for X-radiation were investigated by computer simulations considering the incident and transmitted X-ray spectra for the different studied compositions and they were compared to the properties of the reference materials Pb, Ba and BaSO4 (barite). The results obtained with the simulations indicated the formulated composition of grês ceramic base that presented better attenuation properties considering the X-ray energies used in diagnosis (80, 100 and 150 kV). Ceramic plates based on the formulated compositions that presented lower percentage differences related to Pb were experimentally produced and physically tested as wall coating and protecting barrier. Properties as flexion resistance module, density, load rupture, water absorption and Xradiation attenuation were evaluated for all produced plates.
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.
AudrewFrimaio.pdf (5.16 Mbytes)
Publishing Date
2007-06-22
 